Abstract
Background: Early mobilization and mobility are essential components of the recovery process following surgery and trauma-related hospitalization. In addition to personalized support from physiotherapists and health care professionals, assistive devices such as walkers play a crucial role in facilitating safe and effective mobility.
Objective: This scoping review aims to provide a comprehensive overview of the current state of the literature on the design, sensor technologies, and functional applications of smart walkers and to assess the extent to which existing studies reflect clinical use cases.
Methods: Peer-reviewed English articles published between 2015 and 2024 were identified by searching PubMed, CINAHL, SSCI, and IEEE, focusing on the topic of smart walkers. Secondary analyses and walkers with 2 wheels or fewer were excluded in abstract screening. Study screening and selection were performed according to the Joanna Briggs Institute guidelines for scoping research and reported following the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) guidelines. The Rayyan systematic review management software was used for study selection. The articles included were analyzed with respect to the sensor technologies used, their functional capabilities, and their application scenarios.
Results: Of the 800 articles screened, 44 (5.5%) met the inclusion criteria. Most of these articles were research reports (n=36, 81.8%) and were conducted in laboratory-based environments (n=30, 68.2%). Most studies evaluated smart walkers in asymptomatic populations (n=29, 65.9%), with half (n=22, 50%) involving younger adults. Among the sensor modalities reported, camera-based and light detection and ranging–based sensors were most prevalent for half of the implementations. Light detection and ranging–based sensors can be categorized according to their primary functions: gait analysis (n=11, 25%), collision detection (n=9, 36%), and navigation (n=5, 11.4%). Load sensors (n=10, 22.7%) and ultrasonic sensors (n=11, 25%) were among the most frequently cited sensor modalities in the literature. Load sensors, also known as force sensors, are integrated into the handlebars, frame, forearm supports, or chest pads of smart walkers. These sensors measure the user’s load, providing essential data for calculating body weight support or inferring the user’s intention to move.
Conclusions: The smart walkers described in the literature were predominantly tested in asymptomatic and younger populations. Bridging the gap between current laboratory-based research and real-world clinical environments, as well as the daily lives of end users, remains a critical objective. Addressing the specific needs of older adults through comprehensive requirements analyses and iterative testing continues to be an ongoing challenge, yet these processes can serve as integral components of research and development projects.
Trial Registration: OSF Registries osf.io/ctpf4; https://osf.io/ctpf4
doi:10.2196/78480
Keywords
Introduction
In contemporary society, we are confronted with the dual challenges of an aging population and evolving demands in daily routines. These challenges are compounded by age-related impairments in walking ability, often due to lower limb discomfort [] and/or compromised balance [], which necessitate the use of mobility aids. The selection of appropriate mobility aids (eg, wheelchair, crutches, and walker) has to be tailored to the individual’s remaining functional capacities [].
Such aids are essential not only for addressing mobility issues but also for mitigating the long-term consequences of reduced compensatory ability (eg, muscle atrophy, altered gait patterns, and further decline in balance) []. Without appropriate intervention, this progressive decline may lead to a further reduction in residual capacities, potentially creating a cycle of dependency and physical deterioration [].
Mobility aids are not restricted to indoor use; they are also vital for maintaining autonomy and mobility outside the home, such as for visiting medical practitioners, shopping, or engaging in social activities. The primary target group for these devices is older adults, for whom mobility aids play a vital role in maintaining participation in daily life and preserving independence in later years [].
In hospital settings, individuals remain dependent on mobility aids to prevent the adverse effects of immobility, including muscle atrophy, joint contractures, and psychological deterioration. Although clinical settings typically prioritize disease diagnosis and treatment, preserving mobility and promoting early mobilization [,] with the aid of assistive devices is an essential objective for health care providers []. In this context, walkers and other gait-assisting devices play a crucial role, especially in early mobilization.
Technological advancements in mobility aids have been ongoing for several years, leading to the development of functionally enhanced walkers. These devices now integrate various assistive technologies, such as motorized support for propulsion, navigation systems, balance detection, counter-steering mechanisms in response to balance loss, and compensatory features for sensory deficits [,]. Additionally, smart walkers may serve as valuable tools in biomechanical diagnostics within orthopedic clinics when gait and/or postural analysis are implemented or for individualized risk prediction of falls []. According to Valadão et al [], smart walkers are “...walkers that contain, besides the mechanical structure to support the user, electronics, control systems and sensors, in order to allow a better user experience and minimize the risks of falling.”
The aim of this scoping review is to identify and map the current applications of functionally enhanced walkers, commonly referred to as smart walkers. The study aims to answer the following primary research question: What are the current functions of smart walkers, and in which settings are they applied?
Secondary research questions include the following: (1) Which types of sensors are integrated into smart walkers? (2) What are the specific application scenarios for these devices, including contextual settings and target user groups?
Methods
Study Design
This scoping review was conducted in accordance with the Joanna Briggs Institute guidelines for scoping research and reported following the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) [] guidelines. The literature search was performed in January and February 2025. The study protocol was registered on the Open Science Framework platform (registration number: 10.17605/OSF.IO/CTPF4).
Information Sources and Search Strategy
The search encompassed publications from January 2015 to December 2024, using a predefined search string. The search string for the PubMed database is provided in . The search strings for 4 other databases can be found in . An initial search was performed in PubMed, SSCI, CINAHL, IEEE, and Cochrane Library, which informed the development of a comprehensive search strategy subsequently applied across all sources. Final searches were conducted in the 5 databases. After removing duplicates and screening titles and abstracts, full-text reviews were conducted.
PubMed
- Walker* [Title/Abstract]
- rollator* [Title/Abstract]
- device supported [Title/Abstract]
- walker* [MeSH Terms]
- #1 OR #2 OR #3 OR #4
- smart [Title/Abstract]
- intelligent [Title/Abstract]
- robot* [Title/Abstract]
- artificial [Title/Abstract]
- ai [Title/Abstract]
- #6 OR #7 OR #8 OR #9 OR #10
- DNA [Title/Abstract]
- device-based [Title/Abstract]
- molecular [Title/Abstract]
- Covid* [Title/Abstract]
- exoskeleton
- teaching
- walker* and avant*
- #12 OR #13 OR #14 OR #15 OR #16 OR #17 OR #18
- #5 AND #11 NOT #19
Inclusion and Exclusion Criteria
Articles published in English in peer-reviewed journals that focused on smart walkers and independent walking users were included. Exclusion criteria encompassed secondary analyses (eg, reviews), smart walking aids with 2 wheels or fewer, or studies where the term “walker” referred to nonsmart devices.
Study Selection
The Rayyan (Rayyan Systems Inc) systematic review management software was used for study selection. Four independent reviewers (HB, MW, SS, and NS) initially screened titles and abstracts to exclude articles that did not meet the inclusion criteria. Subsequently, full-text screening was performed independently by 2 of the aforementioned reviewers. Discrepancies were resolved through discussion with a third reviewer until consensus was achieved.
Data Extraction
Data from each included study were extracted independently by HB, MW, NS, and SS using a structured data extraction framework. Any conflicts were resolved through discussion with the principal investigator (NS). The reviewers’ professional backgrounds include doctoral (PhD) degrees in physiotherapy and health sciences, with experience in health technologies related to mobility in older patients, as well as physiotherapy care and therapy for older patients. They also have research experience and have conducted studies on health technologies that address mobility. Furthermore, the researchers are sports scientists and nursing professionals with expertise in geriatric care for older clients and 10 years of experience in clinical gait analysis.
Data extracted from each publication included general publication details (year, author, journal, and country), study population and setting, and characteristics of smart walkers (hardware, software, and technological features such as sensors and feedback mechanisms), as well as technological features (sensors and feedback mechanisms). These data are presented in the Results section.
As per the scoping review methodology, the quality of included studies was not appraised.
Results
Overview
An initial pool of 800 articles was identified for screening (duplicates removed n=59, 7.4%). After title and abstract screening, 666 (83.3%) articles were excluded based on the predefined criteria related to theme and publication period. A total of 75 (9.4%) records were sought for retrieval. Although the original authors were contacted, 2 (0.3%) studies could not be included due to missing full texts. The remaining 73 (9.1%) articles underwent full-text review, leading to the exclusion of 29 (3.6%) studies due to study design, theme of investigation, and design of object or period. Ultimately, 44 (5.5%) articles met the inclusion criteria. The entire selection process is summarized in the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) flowchart [] ().

Description of Included Studies
Of the 800 articles screened, 44 (5.5%) met the predefined inclusion criteria. Geographically, the research was predominantly conducted in Europe (n=19, 43.2%; ).

Most of these studies were research reports (n=36, 81.8%). Sample sizes varied considerably across the included studies, ranging from a minimum of 1 participant to a maximum of 43 participants. A total of 5 (11.4%) studies did not report the number of participants. Most evaluations of smart walkers were conducted exclusively or partially in asymptomatic populations (n=29, 65.9%), with half (n=22, 50%) of the studies involving younger adults. A total of 14 (31.8%) studies involved older adults (6 studies without specifying age group and 1 without any person; ).
| Study, country | Year of publication | N | Setting | Study type | Population |
| Alves et al [], Portugal | 2016 | 6 | Clinical | Research report | Symptomatic and younger adults |
| Caetano et al [], Portugal | 2016 | Not specified | Clinical and rehabilitation | Research report | Not specified |
| Ballesteros et al [], Netherlands, Spain, and Italy | 2016 | 43 | Laboratory and clinical | Research report | Symptomatic, asymptomatic, younger, and older adults |
| Hellström et al [], Sweden | 2016 | 12 | Laboratory | Research report | Asymptomatic, symptomatic, and older adults |
| Valadão et al [], Brazil | 2016 | Not specified | Laboratory | Research report | Asymptomatic |
| Ballesteros et al [], Spain | 2017 | 19 | Rehabilitation | Research report | Symptomatic |
| Mun et al [], Singapore | 2017 | 10 | Laboratory | Research report | Asymptomatic and younger adults |
| Ohnuma et al [], Japan | 2017 | 5 | Not specified | Research report | Asymptomatic and older adults |
| Paulo et al [], Portugal | 2017 | 30 | Laboratory | Research report | Asymptomatic and younger adults |
| Taghvaei et al [], Japan | 2017 | 4 | Not specified | Research report | Asymptomatic and younger adults |
| Zhang and Ye [], not applicable | 2017 | 9 | Laboratory | Research report | Not specified |
| Werner et al [], Germany | 2018 | 42 | Clinical | Randomized controlled trial | Asymptomatic, symptomatic, and older adults |
| Andreetto et al [], Italy | 2019 | 29 | Laboratory | Research report | Asymptomatic, symptomatic, younger, and older adults |
| Ferrari et al [], Italy | 2019 | 29 | Laboratory | Research report | Asymptomatic, symptomatic, and older adults |
| Li et al [], Japan | 2019 | 3 | Laboratory | Research report | Asymptomatic and younger adults |
| Moreira et al [], Portugal | 2019 | 3 | Rehabilitation | Research report | Symptomatic |
| Pérez-Rodríguez et al [], Spain | 2019 | 34 | Clinical | Randomized controlled trial | Symptomatic and older adults |
| Sato et al [], Japan | 2019 | 11 | Community dwelling | Research report | Asymptomatic and older adults |
| Scheidegger et al [], Columbia | 2019 | 5 | Laboratory | Research report | Symptomatic and younger adults |
| Sierra et al [], Columbia | 2019 | 7 | Laboratory | Research report | Asymptomatic and younger adults |
| Werner et al [], Germany | 2019 | 25 | Laboratory | Research report | Symptomatic and older adults |
| Alazem et al [], Canada | 2020 | 5 | Laboratory | Research report | Symptomatic, children, and younger adults |
| Jiménez et al [], Brazil | 2020 | 15 | Laboratory | Research report | Not specified |
| Yeoh et al [], Japan | 2020 | 18 | Not specified | Research | Asymptomatic and younger adults |
| Werner et al [], Germany | 2020 | 33 | Laboratory | Research report | Asymptomatic and older adults |
| Zhao et al [], China | 2020 | Not specified | Laboratory | Research report | Not specified |
| Chang et al [], Taiwan | 2021 | Not specified | Laboratory | Research | Asymptomatic |
| Mostofa et al [], United States | 2021 | 11 | Community dwelling | Research report | Asymptomatic and older adults |
| Moustris et al [], Greece | 2021 | 32 | Rehabilitation | CCT | Asymptomatic, symptomatic, younger, and older adults |
| Orenius et al [], Finland | 2021 | 19 | Not specified | CCT | Older adults |
| Sierra et al [], Columbia | 2021 | 10 | Laboratory | Research report | Asymptomatic and younger adults |
| Sierra et al [], Columbia | 2021 | 10 | Laboratory | Research report | Symptomatic and older adults |
| Zhang et al [], China | 2021 | 8 | Laboratory | Research | Asymptomatic and younger adults |
| Fernandez-Carmona et al [], Spain | 2022 | 11 | Laboratory | Observational study | Younger and older adults |
| Palermo et al [], Portugal | 2022 | 14 | Laboratory | Research report | Asymptomatic and younger adults |
| Jacobs et al [], United States | 2023 | 11 | Laboratory | Observational study | Asymptomatic and younger adults |
| Schwarz et al [], Germany | 2023 | Not applicable | Laboratory | Research report | Younger adults |
| Wang et al [], China | 2023 | 1 | Laboratory | Research report | Asymptomatic |
| Gong et al [], China | 2024 | 3 | Laboratory | Research | Asymptomatic and younger adults |
| Jiang et al [], China | 2024 | 3 | Laboratory | Observational study | Asymptomatic and younger adults |
| Machado et al [], Brazil | 2024 | 20 | Laboratory | Observational study | Asymptomatic and younger adults |
| Mori et al [], Japan | 2024 | 5 | Laboratory | Research report | Asymptomatic and younger adults |
| Sierra et al [], United Kingdom | 2024 | 14 | Laboratory | Research report | Asymptomatic and younger adults |
| Zhang et al [], Japan | 2024 | 20 | Community dwelling | Research report | Asymptomatic |
aNo information about age.
bCCT: controlled clinical trial.
cNo information about health status.
Settings and Participants
The studies were conducted across various settings. Investigations involving smart walkers were most frequently conducted in laboratory-based environments (n=30, 68.2%).
Four groups of participants were evident in the articles included: symptomatic children or younger adults (n=5, 11.4%), asymptomatic younger adults (n=19, 43.2%), symptomatic older adults (n=8, 18.2%), and asymptomatic older adults (n=9, 20.4%). Several articles did not specify the age (n=6, 13.6%) or health status (n=5, 11.4%) of participants. A total of 4 (9.1%) articles provided no information on the age and health status. As there were studies with multiple participant groups, the number of participant groups exceeded the number of articles. The group of participants consisting of asymptomatic younger adults was the most frequently studied group across the articles (n=19, 43.2%; , ).

Walker-Specific Sensor Technologies and Functionalities
The included articles described various types of sensors and functions that constitute the extent of smart technology integrated into modern walkers. The sensors used were fundamental to the operation of these intelligent walkers. They encompassed a range of sensor types, including camera systems (2D cameras, depth cameras, and infrared cameras), optical sensors that used laser lights (2D laser scanners and light detection and ranging [LiDAR]), force and load sensors, ultrasound sensors, and inertial measurement units (IMUs; ).
Among the sensor modalities reported, camera- and LiDAR-based sensors were the most prevalent, accounting for half of the implementations. Camera sensors were described either as standard 2D cameras (n=11, 25%) [,,,,,,,,,,] or depth cameras. Depth cameras were used for multiple purposes, including gait analysis (n=3, 6.8%) [,,] and intention recognition (n=3, 6.8%) [,,], by capturing gaze direction. Additionally, depth cameras were used for collision avoidance through object detection (n=4, 9.1%) [,,,], and 1 (2.3%) study specifically described the use of depth cameras for fall prediction purposes []. LiDAR-based sensors can be categorized according to their primary functions: gait analysis (n=11, 25%), collision detection (n=9, 20.5%), and navigation (n=5, 11.4%).
In addition, load sensors (n=10, 22.7%) and ultrasonic sensors (n=11, 25%) were among the most frequently cited sensor modalities in the literature. Furthermore, load and force sensors were typically integrated into the handlebars of smart walkers (n=10, 22.7%) [,,,,,,,,,]. These sensors were described as “the simplest approach to onboard sensor-based gait analysis” [] and were used to assess the user’s balance during ambulation []. Zhao et al [] further detailed handgrip pressure sensors that can potentially prevent falls by detecting abnormal pressure or rapid pressure changes, indicating a fall risk. For instance, the smart walker developed by Ballesteros et al [] incorporated force sensors in the handlebars alongside encoders to measure wheel rotation.
Beyond handlebar-mounted sensors, force sensors were also embedded elsewhere in the walker’s structure, such as in the frame, forearm supports, or chest pads (n=7, 15.9%) [,,,-]. Sensors placed within the frame measured the user’s weight load, providing critical data for calculating body weight support (n=3, 6.8%) [,,]. Additionally, Machado et al [] and Jiménez et al [] reported on force sensors located in forearm supports, which were used to infer the user’s intention to move, thereby enabling more responsive and adaptive assistance.
Ultrasound sensors were described in a quarter of the articles (n=11, 25%) and were used for collision avoidance [,,,,,,,,,,]. IMUs were described with a similar frequency (n=12, 27.3%) [,,,,,,,,,-]. An analysis of their functions revealed that they were mainly used to determine position and orientation, measure accelerations, record angular velocities, or support odometry sensors.
| Functions | Sensors |
| Safety and collision detection | LiDAR, microphone, ultrasound sensors, camera, and infrared |
| Navigation | LiDAR, optical encoder, and IMUs |
| Propulsive support and reduction of speed | Odometry sensors, force and load sensors, and IMUs |
| Body weight support | Force and load sensors |
| Intention to move | Force and load sensors and camera (detecting gaze) |
| Movement analysis (gait, balance, and postural control) | LiDAR, depth camera, and 2D laser range finder |
| Fall risk detection and falls | 3D load sensors and depth camera |
aLiDAR: light detection and ranging.
bIMU: inertial measurement unit.
With regard to sensory-based feedback generated, the following distinctions can be reported: user feedback, which provides relevant information on, for example, navigation details or collision warning during the use of the smart walker (), or observer feedback, which, for example, provides valuable additional information such as gait-related or system-relevant measurement data () to the observer or therapist.
| Category of observer feedback | Entries, n (%) |
| Haptic or tactile | 10 (22.7) |
| Visual, user interface or navigation | 13 (29.6) |
| Assistive control-based feedback | 7 (15.9) |
| Virtual, multimodal or social | 5 (11.4) |
| No user feedback | 10 (22.7) |
| Unclear | 3 (6.8) |
| Category of observer feedback | Entries, n (%) |
| Objective measurement data, gait analysis and sensor data | 27 (61.4) |
| User experience, interaction and system data | 14 (31.8) |
| No observer feedback | 10 (22.7) |
| Unclear | 4 (9.1) |
Discussion
Principal Findings
This scoping review was conducted to provide a comprehensive overview of the current application settings, sensors, and functionalities of smart walkers.
Various sensors, such as LiDAR, depth camera, and 2D laser range finder, which could be used for a clinical assessment of the gait pattern or for measuring balance, have been integrated into smart walkers. Analysis of the intended use of sensors revealed a wide variety of applications. For instance, IMUs were mainly used to determine position and orientation, measure system accelerations, record angular velocities, and support odometry. The gait analysis functionality and the validity of the measured parameters depend on the sensor types used and their placement on the smart walker.
Analysis of the included studies indicates that validation data for gait-related sensor technology are often missing or only partially reported. Only 8 (22.9%) of the 35 studies measuring gait-relevant data used reference systems such as the one used in the study by Werner et al [], IMU-based systems (MTw Awinda, Xsens Technologies, B.V.) [], or a marker-based camera system operating at 120 Hz (Vicon motion analysis system) []. These studies provided the most methodologically robust evidence regarding measurement accuracy and are best suited for comparison with established clinical measurement systems. An additional 17 (38.6%) studies reported some form of validation but without a reference standard, mostly in the form of internal error measures (eg, root mean square error, difference metrics, and trial comparisons). While these data provide valuable technical insights, they allow only limited conclusions regarding external validity. Some articles provided no information on the validation of gait sensors, which is partly due to the studies’ focus. In many studies, the primary objective was different, such as navigation, safety, human-robot interaction, or technology design, meaning that gait analysis was only of marginal or no relevance. Overall, there is a clear gap between technical innovation and methodological transparency: although smart walker systems increasingly integrate complex sensor sets, validation against established gold standards remains uncommon. This lack of consistent validation limits the transferability of findings to clinical practice.
This review demonstrates that smart walkers that have been investigated in laboratory-oriented settings and among user populations are not representative of real-world applications. Most research has taken place in controlled laboratory environments and primarily involves asymptomatic and/or younger users of smart walkers. In contrast, older adults (representing an increasing global aging population) are key drivers of the expanding market for walking aids and walkers []. It is undisputed that younger adults have fewer functional limitations, better balance abilities, and overall exhibit fewer fall-related risk factors than older adults. As noted by Maranesi et al [], research in this field should move beyond focusing solely on the technical functionality of gait devices and walkers. Our results illustrate a gap in effectively incorporating these devices into relevant settings, such as clinical environments or the daily lives of end users. This underscores the need for a comprehensive understanding of the physical, social, and cognitive needs of older adults. In 2025, a funded research and development initiative was launched in Germany to develop a prototype of a smart walker. The SmartRoll project adopts a user-centered study design, systematically identifying the needs of patients, professional caregivers, and physiotherapists []. These insights are subsequently evaluated with the target population—patients on an acute geriatric ward—as part of an integrated research and development effort. Additionally, the project involves the integration and testing of sensors capable of performing gait analysis in this vulnerable group of older adults. This scoping review indicates that the search for smart walkers in the clinical setting implies their use for research purposes within clinical environments. The relevance of smart walkers in clinical contexts is driven by the urgent need to address age-related skill decline [] and mobility impairment []. This paper is embedded in a study that examines the current relevance of deploying smart rollators in clinical settings.
Older individuals who rely on assistive devices often do so due to underlying health conditions or following adverse events such as falls. Consequently, it is not surprising that users of walkers exhibit a fourfold increased risk of falls compared to individuals walking without such aids []. This population is particularly vulnerable during acute hospital stays. The use of smart walkers equipped with gait analysis and balance measurement functions could potentially be used in hospital settings to assess fall risk among patients. Indicators of fall risk are primarily identified through parameters that suggest an unstable gait balance and gait pattern. These parameters include, but are not limited to, foot angle at contact, step length, maximum foot height, and a high SD in step characteristics [].
It should be noted that research comparing 2-, 3-, and 4-wheeled walkers is limited. Two-wheeled walkers often need to be partially lifted, requiring strength and coordination and affecting gait parameters. As the poor maneuverability and lower lateral stability of 2-wheeled walkers may pose additional risk factors [], they were excluded from this review.
Conclusions
The smart walkers described in the literature were predominantly tested in asymptomatic and young populations. Developing smart walkers that explicitly address the specific needs of older adults—through systematic requirements analyses—and iterative testing throughout the development process remains an ongoing challenge. Integrating these steps as core components of research and development projects is essential to enhance clinical relevance.
Acknowledgments
The authors would like to thank Moritz Waage for his support with data extraction.
Funding
This work was supported by Federal Ministry of Education and Research (Germany; grant 16SV9335).
Authors' Contributions
NS conceptualized the scoping review; contributed substantially to drafting the Methods, Results, Discussion, and Conclusions sections; and prepared the original manuscript. HB contributed through review and editing of the manuscript. SS contributed to drafting the Introduction and Discussion sections and supervised the study.
Conflicts of Interest
None declared.
Multimedia Appendix 1
Search strings for the SSCI, CINAHL, IEEE Xplore, and Cochrane Library databases.
DOCX File, 18 KBReferences
- Osoba MY, Rao AK, Agrawal SK, Lalwani AK. Balance and gait in the elderly: a contemporary review. Laryngoscope Investig Otolaryngol. Feb 2019;4(1):143-153. [CrossRef] [Medline]
- Young WR, Ellmers TJ, Kinrade NP, Cossar J, Cocks AJ. Re-evaluating the measurement and influence of conscious movement processing on gait performance in older adults: development of the Gait-Specific Attentional Profile. Gait Posture. Sep 2020;81:73-77. [CrossRef] [Medline]
- Werner C, Ullrich P, Geravand M, Peer A, Hauer K. Evaluation studies of robotic rollators by the user perspective: a systematic review. Gerontology. 2016;62(6):644-653. [CrossRef] [Medline]
- Wang J, Li Y, Yang GY, Jin K. Age-related dysfunction in balance: a comprehensive review of causes, consequences, and interventions. Aging Dis. 2024;16(2):714-737. [CrossRef] [Medline]
- Peterson KF, Adams-Price C. Fear of dependency and life-space mobility as predictors of attitudes toward assistive devices in older adults. Int J Aging Hum Dev. Apr 2022;94(3):273-289. [CrossRef] [Medline]
- Bertrand K, Raymond MH, Miller WC, Martin Ginis KA, Demers L. Walking aids for enabling activity and participation: a systematic review. Am J Phys Med Rehabil. Dec 2017;96(12):894-903. [CrossRef] [Medline]
- Schaller SJ, Anstey M, Blobner M, et al. Early, goal-directed mobilisation in the surgical intensive care unit: a randomised controlled trial. Lancet. Oct 1, 2016;388(10052):1377-1388. [CrossRef] [Medline]
- Okada Y, Unoki T, Matsuishi Y, Egawa Y, Hayashida K, Inoue S. Early versus delayed mobilization for in-hospital mortality and health-related quality of life among critically ill patients: a systematic review and meta-analysis. J Intensive Care. 2019;7:57. [CrossRef] [Medline]
- Grund S, Gordon AL, van Balen R, et al. European consensus on core principles and future priorities for geriatric rehabilitation: consensus statement. Eur Geriatr Med. Apr 2020;11(2):233-238. [CrossRef] [Medline]
- Sierra M SD, Garzón M, Múnera M, Cifuentes CA. Human-robot-environment interaction interface for smart walker assisted gait: AGoRA Walker. Sensors (Basel). Jun 30, 2019;19(13):2897. [CrossRef] [Medline]
- Sun Y, Xiao C, Chen L, et al. A review of intelligent walking support robots: aiding sit-to-stand transition and walking. IEEE Trans Neural Syst Rehabil Eng. 2024;32:1355-1369. [CrossRef] [Medline]
- Parsons R, Blythe RD, Cramb SM, McPhail SM. Inpatient fall prediction models: a scoping review. Gerontology. 2023;69(1):14-29. [CrossRef] [Medline]
- Valadão C, Caldeira E, Bastos-Filho T, Frizera-Neto A, Carelli R. A new controller for a smart walker based on human-robot formation. Sensors (Basel). Jul 19, 2016;16(7):1116. [CrossRef] [Medline]
- Tricco AC, Lillie E, Zarin W, et al. PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation. Ann Intern Med. Oct 2, 2018;169(7):467-473. [CrossRef] [Medline]
- Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. Mar 29, 2021;372:n71. [CrossRef] [Medline]
- Alves J, Seabra E, Caetano I, et al. Considerations and mechanical modifications on a smart walker. Presented at: 2016 International Conference on Autonomous Robot Systems and Competitions (ICARSC); May 4-6, 2016. [CrossRef]
- Caetano I, Alves J, Goncalves J, Martins M, Santos CP. Development of a biofeedback approach using body tracking with active depth sensor in ASBGo Smart Walker. Presented at: 2016 International Conference on Autonomous Robot Systems and Competitions (ICARSC); May 4-6, 2016. [CrossRef]
- Ballesteros J, Urdiales C, Martinez AB, van Dieën JH. On gait analysis estimation errors using force sensors on a smart rollator. Sensors. Nov 10, 2016;16(11):1896. [CrossRef]
- Hellström T, Lindahl O, Bäcklund T, et al. An intelligent rollator for mobility impaired persons, especially stroke patients. J Med Eng Technol. Jul 2016;40(5):270-279. [CrossRef] [Medline]
- Ballesteros J, Urdiales C, Martinez AB, Tirado M. Automatic assessment of a rollator-user’s condition during rehabilitation using the i-Walker platform. IEEE Trans Neural Syst Rehabil Eng. Nov 2017;25(11):2009-2017. [CrossRef] [Medline]
- Mun KR, Lim SB, Guo Z, Yu H. Biomechanical effects of body weight support with a novel robotic walker for over-ground gait rehabilitation. Med Biol Eng Comput. Feb 2017;55(2):315-326. [CrossRef] [Medline]
- Ohnuma T, Lee G, Chong NY. Development of JARoW-II active robotic walker reflecting pelvic movements while walking. Intel Serv Robot. Apr 2017;10(2):95-107. [CrossRef]
- Paulo J, Peixoto P, Nunes UJ. ISR-AIWALKER: robotic walker for intuitive and safe mobility assistance and gait analysis. IEEE Trans Hum Mach Syst. Dec 2017;47(6):1110-1122. [CrossRef]
- Taghvaei S, Jahanandish MH, Kosuge K. Autoregressive-moving-average hidden Markov model for vision-based fall prediction-an application for walker robot. Assist Technol. 2017;29(1):19-27. [CrossRef] [Medline]
- Zhang H, Ye C. RGB-D camera based walking pattern recognition by support vector machines for a smart rollator. Int J Intell Robot Appl. Feb 2017;1(1):32-42. [CrossRef] [Medline]
- Werner C, Moustris GP, Tzafestas CS, Hauer K. User-oriented evaluation of a robotic rollator that provides navigation assistance in frail older adults with and without cognitive impairment. Gerontology. 2018;64(3):278-290. [CrossRef] [Medline]
- Andreetto M, Divan S, Ferrari F, Fontanelli D, Palopoli L, Prattichizzo D. Combining haptic and bang-bang braking actions for passive robotic walker path following. IEEE Trans Haptics. 2019;12(4):542-553. [CrossRef] [Medline]
- Ferrari F, Divan S, Guerrero C, et al. Human–robot interaction analysis for a smart walker for elderly: the ACANTO interactive guidance system. Int J Soc Robotics. May 2020;12:479-492. [CrossRef]
- Li P, Yamada Y, Wan X, et al. Gait-phase-dependent control using a smart walker for physical training. IEEE Int Conf Rehabil Robot. 2019;2019:843-848. [CrossRef] [Medline]
- Moreira R, Alves J, Matias A, Santos C. Smart and assistive walker – ASBGo: rehabilitation robotics: a smart–walker to assist ataxic patients. In: Sequeira JS, editor. Robotics in Healthcare: Field Examples and Challenges. Springer; 2019:37-68. [CrossRef]
- Pérez-Rodríguez R, Moreno-Sánchez PA, Valdés-Aragonés M, et al. FriWalk robotic walker: usability, acceptance and UX evaluation after a pilot study in a real environment. Disabil Rehabil Assist Technol. Aug 2020;15(6):718-727. [CrossRef] [Medline]
- Sato W, Tsuchida Y, Li P, Hasegawa T, Yamada Y, Uchiyama Y. Identifying the effects of assistive and resistive guidance on the gait of elderly people using a smart walker. IEEE Int Conf Rehabil Robot. Jun 2019;2019:198-203. [CrossRef] [Medline]
- Scheidegger WM, de Mello RC, Sierra M SD, et al. A novel multimodal cognitive interaction for walker-assisted rehabilitation therapies. Presented at: 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR); Jun 24-28, 2019. [CrossRef]
- Werner C, Chalvatzaki G, Papageorgiou XS, Tzafestas CS, Bauer JM, Hauer K. Assessing the concurrent validity of a gait analysis system integrated into a smart walker in older adults with gait impairments. Clin Rehabil. Oct 2019;33(10):1682-1687. [CrossRef] [Medline]
- Alazem H, McCormick A, Nicholls SG, Vilé E, Adler R, Tibi G. Development of a robotic walker for individuals with cerebral palsy. Disabil Rehabil Assist Technol. Aug 2020;15(6):643-651. [CrossRef] [Medline]
- Jiménez MF, Mello RC, Bastos T, Frizera A. Assistive locomotion device with haptic feedback for guiding visually impaired people. Med Eng Phys. Jun 2020;80:18-25. [CrossRef] [Medline]
- Yeoh WL, Choi J, Loh PY, Saito S, Muraki S. The effect of horizontal forces from a smart walker on gait and perceived exertion. Assist Technol. Mar 4, 2022;34(2):204-212. [CrossRef] [Medline]
- Werner C, Geravand M, Korondi PZ, Peer A, Bauer JM, Hauer K. Evaluating the sit-to-stand transfer assistance from a smart walker in older adults with motor impairments. Geriatr Gerontol Int. Apr 2020;20(4):312-316. [CrossRef] [Medline]
- Zhao X, Zhu Z, Liu M, et al. A smart robotic walker with intelligent close-proximity interaction capabilities for elderly mobility safety. Front Neurorobot. 2020;14:575889. [CrossRef] [Medline]
- Chang YH, Sahoo N, Chen JY, Chuang SY, Lin HW. ROS-based smart walker with fuzzy posture judgement and power assistance. Sensors (Basel). Mar 29, 2021;21(7):2371. [CrossRef] [Medline]
- Mostofa N, Feltner C, Fullin K, et al. A smart walker for people with both visual and mobility impairment. Sensors (Basel). May 17, 2021;21(10):3488. [CrossRef] [Medline]
- Moustris G, Kardaris N, Tsiami A, et al. The i-Walk lightweight assistive rollator: first evaluation study. Front Robot AI. 2021;8:677542. [CrossRef] [Medline]
- Ingemar Orenius T, Paloniemi S, Hurri H, et al. Piloting a smart rollator: user experiences with technology-related motivation and physical activity. Gerontechnology. Jan 2021;20(2):1-10. [CrossRef]
- Sierra M SD, Múnera M, Provot T, Bourgain M, Cifuentes CA. Evaluation of physical interaction during walker-assisted gait with the AGoRA Walker: strategies based on virtual mechanical stiffness. Sensors (Basel). May 7, 2021;21(9):3242. [CrossRef] [Medline]
- Sierra M SD, Garcia A DE, Otálora S, et al. Assessment of a robotic walker in older adults with Parkinson’s disease in daily living activities. Front Neurorobot. 2021;15:742281. [CrossRef] [Medline]
- Zhang C, Guo S, Xi FJ. Man-machine interaction-based motion control of a robotic walker. Technol Health Care. 2021;29(4):749-769. [CrossRef] [Medline]
- Fernandez-Carmona M, Ballesteros J, Díaz-Boladeras M, Parra-Llanas X, Urdiales C, Gómez-de-Gabriel JM. Walk-IT: an open-source modular low-cost smart rollator. Sensors (Basel). Mar 8, 2022;22(6):2086. [CrossRef] [Medline]
- Palermo M, Lopes JM, André J, Matias AC, Cerqueira J, Santos CP. A multi-camera and multimodal dataset for posture and gait analysis. Sci Data. Oct 6, 2022;9(1):603. [CrossRef] [Medline]
- Jacobs M, Stramel DM, Shair M, Agrawal SK. Evaluating gait stability and muscle activation in different hand holding conditions using the robotic walker-mTPAD. Sensors (Basel). Jun 28, 2023;23(13):5996. [CrossRef] [Medline]
- Schwarz M, Gauda V, Kaiser M, Kuttruff HKJ, Rentzsch J, Thür M. Networked multi-sensor rollator with AI-assisted fall detection. Presented at: 2023 IEEE 36th International Symposium on Computer-Based Medical Systems (CBMS); Jun 22-24, 2023. [CrossRef]
- Wang W, Gong T, Song Z, Wang Z, Ji J. Simulation study on assist-as-needed control of a rehabilitation robotic walker. Technol Health Care. 2023;31(S1):293-302. [CrossRef] [Medline]
- Gong T, Chen D, Wang G, et al. Multimodal fusion and human-robot interaction control of an intelligent robot. Front Bioeng Biotechnol. 2024;11:1310247. [CrossRef] [Medline]
- Jiang X, Zong S, Huang J. Lower limb motion measurements during walking by setting rotation angle and period of the motor for driving the chest pad of a rollator. Presented at: 2024 International Symposium on Intelligent Robotics and Systems (ISoIRS); Jun 14-16, 2024. [CrossRef]
- Machado F, Loureiro M, Bezerra M, Zimerer C, Mello R, Frizera A. Virtual obstacle avoidance strategy: navigating through a complex environment while interacting with virtual and physical elements. Sensors (Basel). Sep 25, 2024;24(19):6212. [CrossRef] [Medline]
- Mori Y, Yokoyama S, Yamashita T, Kawamura H, Mori M. Development of assistance level adjustment function for variable load on a forearm-supported robotic walker. Sensors (Basel). Oct 6, 2024;24(19):6456. [CrossRef] [Medline]
- Sierra M SD, Harris N, Múnera M, Cifuentes CA. Socially assistive walker for daily living assistance in older adults. Front Robot AI. 2024;11:1401663. [CrossRef] [Medline]
- Zhang B, Wang Z, Li Z. Mobility Aid Design for the Elderly (MADE): a design thinking approach using a smart walker as a case study. Humanit Soc Sci Commun. Nov 5, 2024;11:1469. [CrossRef]
- Bora D. Walkers and rollators market size, share & trends analysis report. Straits Research; 2024. URL: https://straitsresearch.com/report/walkers-and-rollators-market [Accessed 2025-06-03]
- Maranesi E, Amabili G, Cucchieri G, Bolognini S, Margaritini A, Bevilacqua R. Understanding the acceptance of IoT and social assistive robotics for the healthcare sector: a review of the current user-centred applications for the older users. In: Scataglini S, Imbesi S, Marques G, editors. Internet of Things for Human-Centered Design. Springer; 2022:331-351. [CrossRef]
- Strutz N, Meyer-Feil T, Schwesig R, Schulze S, Gissendanner H. Development of a smart walker for clinical settings: a protocol of an exploratory mixed-methods study. BMJ Open. Dec 31, 2025;15(12):e105342. [CrossRef] [Medline]
- Roman de Mettelinge T, Cambier D. Understanding the relationship between walking aids and falls in older adults: a prospective cohort study. J Geriatr Phys Ther. 2015;38(3):127-132. [CrossRef] [Medline]
- Nickerson KA, Diaz K, Muir BC. Circumstances of falls among older adult walker users in long-term care and the associated walker design deficits. Assist Technol. May 3, 2024;36(3):248-253. [CrossRef] [Medline]
Abbreviations
| IMU: inertial measurement unit |
| LiDAR: light detection and ranging |
| PRISMA: Preferred Reporting Items for Systematic Reviews and Meta-Analyses |
| PRISMA-ScR: Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews |
Edited by Alessandro Scano; submitted 03.Jun.2025; peer-reviewed by Arve Opheim, Giulio Amabili; final revised version received 03.Feb.2026; accepted 20.Feb.2026; published 26.May.2026.
Copyright© Nicole Strutz, Hanna Brodowski, Stephan Schulze. Originally published in JMIR Rehabilitation and Assistive Technology (https://rehab.jmir.org), 26.May.2026.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Rehabilitation and Assistive Technology, is properly cited. The complete bibliographic information, a link to the original publication on https://rehab.jmir.org/, as well as this copyright and license information must be included.