<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="2.0">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JRAT</journal-id>
      <journal-id journal-id-type="nlm-ta">JMIR Rehabil Assist Technol</journal-id>
      <journal-title>JMIR Rehabilitation and Assistive Technologies</journal-title>
      <issn pub-type="epub">2369-2529</issn>
      <publisher>
        <publisher-name>JMIR Publications</publisher-name>
        <publisher-loc>Toronto, Canada</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">v9i2e33521</article-id>
      <article-id pub-id-type="pmid">35653180</article-id>
      <article-id pub-id-type="doi">10.2196/33521</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Review</subject>
        </subj-group>
        <subj-group subj-group-type="article-type">
          <subject>Review</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Inertial Measurement Units and Application for Remote Health Care in Hip and Knee Osteoarthritis: Narrative Review</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="editor">
          <name>
            <surname>Leung</surname>
            <given-names>Tiffany</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Kobsar</surname>
            <given-names>Dylan</given-names>
          </name>
        </contrib>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Li</surname>
            <given-names>Linda</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib id="contrib1" contrib-type="author" equal-contrib="yes">
          <name name-style="western">
            <surname>Rose</surname>
            <given-names>Michael J.</given-names>
          </name>
          <degrees>BSE</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-5400-2461</ext-link>
        </contrib>
        <contrib id="contrib2" contrib-type="author" equal-contrib="yes">
          <name name-style="western">
            <surname>Costello</surname>
            <given-names>Kerry E</given-names>
          </name>
          <degrees>BSE, MSc, PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-5928-1471</ext-link>
        </contrib>
        <contrib id="contrib3" contrib-type="author">
          <name name-style="western">
            <surname>Eigenbrot</surname>
            <given-names>Samantha</given-names>
          </name>
          <degrees>BSc, MSc</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-4968-0639</ext-link>
        </contrib>
        <contrib id="contrib4" contrib-type="author">
          <name name-style="western">
            <surname>Torabian</surname>
            <given-names>Kaveh</given-names>
          </name>
          <degrees>BSc</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-4265-7345</ext-link>
        </contrib>
        <contrib id="contrib5" contrib-type="author" corresp="yes">
          <name name-style="western">
            <surname>Kumar</surname>
            <given-names>Deepak</given-names>
          </name>
          <degrees>BSc, MPT, PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <address>
            <institution>Department of Physical Therapy &#38; Athletic Training</institution>
            <institution>Boston University College of Health &#38; Rehabilitation Sciences: Sargent College</institution>
            <addr-line>635 Commonwealth Avenue</addr-line>
            <addr-line>Boston, MA, 02215</addr-line>
            <country>United States</country>
            <phone>1 617 358 3125</phone>
            <email>kumard@bu.edu</email>
          </address>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-1728-484X</ext-link>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label>1</label>
        <institution>Department of Physical Therapy &#38; Athletic Training</institution>
        <institution>Boston University College of Health &#38; Rehabilitation Sciences: Sargent College</institution>
        <addr-line>Boston, MA</addr-line>
        <country>United States</country>
      </aff>
      <aff id="aff2">
        <label>2</label>
        <institution>Division of Rheumatology, Department of Medicine</institution>
        <institution>Boston University School of Medicine</institution>
        <addr-line>Boston, MA</addr-line>
        <country>United States</country>
      </aff>
      <author-notes>
        <corresp>Corresponding Author: Deepak Kumar <email>kumard@bu.edu</email></corresp>
      </author-notes>
      <pub-date pub-type="collection">
        <season>Apr-Jun</season>
        <year>2022</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>2</day>
        <month>6</month>
        <year>2022</year>
      </pub-date>
      <volume>9</volume>
      <issue>2</issue>
      <elocation-id>e33521</elocation-id>
      <history>
        <date date-type="received">
          <day>10</day>
          <month>9</month>
          <year>2021</year>
        </date>
        <date date-type="rev-request">
          <day>9</day>
          <month>11</month>
          <year>2021</year>
        </date>
        <date date-type="rev-recd">
          <day>18</day>
          <month>2</month>
          <year>2022</year>
        </date>
        <date date-type="accepted">
          <day>6</day>
          <month>5</month>
          <year>2022</year>
        </date>
      </history>
      <copyright-statement>©Michael J. Rose, Kerry E Costello, Samantha Eigenbrot, Kaveh Torabian, Deepak Kumar. Originally published in JMIR Rehabilitation and Assistive Technology (https://rehab.jmir.org), 02.06.2022.</copyright-statement>
      <copyright-year>2022</copyright-year>
      <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
        <p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Rehabilitation and Assistive Technology, is properly cited. The complete bibliographic information, a link to the original publication on https://rehab.jmir.org/, as well as this copyright and license information must be included.</p>
      </license>
      <self-uri xlink:href="https://rehab.jmir.org/2022/2/e33521" xlink:type="simple"/>
      <abstract>
        <sec sec-type="background">
          <title>Background</title>
          <p>Measuring and modifying movement-related joint loading is integral to the management of lower extremity osteoarthritis (OA). Although traditional approaches rely on measurements made within the laboratory or clinical environments, inertial sensors provide an opportunity to quantify these outcomes in patients’ natural environments, providing greater ecological validity and opportunities to develop large data sets of movement data for the development of OA interventions.</p>
        </sec>
        <sec sec-type="objective">
          <title>Objective</title>
          <p>This narrative review aimed to discuss and summarize recent developments in the use of inertial sensors for assessing movement during daily activities in individuals with hip and knee OA and to identify how this may translate to improved remote health care for this population.</p>
        </sec>
        <sec sec-type="methods">
          <title>Methods</title>
          <p>A literature search was performed in November 2018 and repeated in July 2019 and March 2021 using the PubMed and Embase databases for publications on inertial sensors in hip and knee OA published in English within the previous 5 years. The search terms encompassed both OA and wearable sensors. Duplicate studies, systematic reviews, conference abstracts, and study protocols were also excluded. One reviewer screened the search result titles by removing irrelevant studies, and 2 reviewers screened study abstracts to identify studies using inertial sensors as the main sensing technology and a primary outcome related to movement quality. In addition, after the March 2021 search, 2 reviewers rescreened all previously included studies to confirm their relevance to this review.</p>
        </sec>
        <sec sec-type="results">
          <title>Results</title>
          <p>From the search process, 43 studies were determined to be relevant and subsequently included in this review. Inertial sensors have been successfully implemented for assessing the presence and severity of OA (n=11), assessing disease progression risk and providing feedback for gait retraining (n=7), and remotely monitoring intervention outcomes and identifying potential responders and nonresponders to interventions (n=14). In addition, studies have validated the use of inertial sensors for these applications (n=8) and analyzed the optimal sensor placement combinations and data input analysis for measuring different metrics of interest (n=3). These studies show promise for remote health care monitoring and intervention delivery in hip and knee OA, but many studies have focused on walking rather than a range of activities of daily living and have been performed in small samples (&#60;100 participants) and in a laboratory rather than in a real-world environment.</p>
        </sec>
        <sec sec-type="conclusions">
          <title>Conclusions</title>
          <p>Inertial sensors show promise for remote monitoring, risk assessment, and intervention delivery in individuals with hip and knee OA. Future opportunities remain to validate these sensors in real-world settings across a range of activities of daily living and to optimize sensor placement and data analysis approaches.</p>
        </sec>
      </abstract>
      <kwd-group>
        <kwd>wearable technology</kwd>
        <kwd>accelerometer</kwd>
        <kwd>gyroscope</kwd>
        <kwd>magnetometer</kwd>
        <kwd>remote monitoring</kwd>
        <kwd>biofeedback</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="introduction">
      <title>Introduction</title>
      <sec>
        <title>Background</title>
        <p>Delivery of care and assessment of outcomes in patients’ natural environments have made large strides in recent years. The COVID-19 pandemic has further created a need for and accelerated the adoption of remote approaches to health care. Wearable sensors, which are used to describe small, lightweight measurement devices that can be worn on the body [<xref ref-type="bibr" rid="ref1">1</xref>], have become integral to models of remote care and assessment. These devices can be worn directly on the body or within an accessory (eg, a watch) without altering the user’s natural behavior.</p>
        <p>Osteoarthritis (OA) is a mechanically driven disorder and a leading cause of disability in middle-aged and older age adults [<xref ref-type="bibr" rid="ref2">2</xref>]. The burden of OA is primarily due to the greater prevalence of knee and hip OA [<xref ref-type="bibr" rid="ref3">3</xref>], including those who undergo joint replacement surgery for hip or knee OA [<xref ref-type="bibr" rid="ref4">4</xref>]. In people with hip or knee OA, abnormal joint loading during daily activities has been associated with pathogenesis [<xref ref-type="bibr" rid="ref5">5</xref>], driving interest in assessing the relationships between repetitive loading during everyday movements and disease outcomes and interventions to alter these loads [<xref ref-type="bibr" rid="ref6">6</xref>]. Although there is a large body of literature on understanding movement patterns during daily activities in people with knee or hip OA, a majority of the prior work has used laboratory or clinical assessments, which have limited ecological validity [<xref ref-type="bibr" rid="ref7">7</xref>]. Furthermore, the gold standard for measuring human movement, optical motion capture, requires expensive equipment, skilled technicians, and a large calibrated measurement space, limiting its deployment on a large scale. In contrast, wearable technology can provide large volumes of data from real-world settings with relative ease. These data could improve health care quality by allowing remote monitoring to inform treatment planning [<xref ref-type="bibr" rid="ref8">8</xref>], for remote care delivery to address provider and patient time constraints [<xref ref-type="bibr" rid="ref9">9</xref>], and for promoting active patient engagement through actionable insights [<xref ref-type="bibr" rid="ref9">9</xref>]. Thus, wearable sensors offer tremendous opportunities to advance research and care for people with hip or knee OA, including those who undergo joint replacement surgery, most frequently total hip arthroplasty (THA) or total knee arthroplasty (TKA) of the arthritic joint.</p>
        <p>The most common wearable movement sensors that have been used for OA applications are accelerometers, gyroscopes, and magnetometers. Accelerometers measure the applied acceleration (ie, rate of change of linear velocity) along a sensitive axis [<xref ref-type="bibr" rid="ref10">10</xref>]. Gyroscopes measure angular velocity (ie, the rate of change of angular motion) within a rotating reference frame [<xref ref-type="bibr" rid="ref11">11</xref>]. Magnetometers capture data that can provide heading information, including body orientation, by sensing Earth’s gravitational field [<xref ref-type="bibr" rid="ref12">12</xref>]. All 3 of these sensors have limitations: accelerometers suffer from signal drift [<xref ref-type="bibr" rid="ref13">13</xref>], poor reliability in measuring nondynamic events [<xref ref-type="bibr" rid="ref14">14</xref>], and the impact of gravity on acceleration signals [<xref ref-type="bibr" rid="ref12">12</xref>]; gyroscopes experience problems with drift, particularly during turning movements [<xref ref-type="bibr" rid="ref11">11</xref>]; and magnetometers can be affected by other magnetic fields (eg, nearby ferromagnetic objects) [<xref ref-type="bibr" rid="ref15">15</xref>]. Consequently, these technologies are often used in combination, especially as inertial measurement units (IMUs; also known as <italic>inertial sensors</italic>), consisting of an accelerometer, gyroscope, and sometimes a magnetometer. Inertial sensors are relatively inexpensive, small, lightweight, and unobtrusive, allowing for implementation in large cohorts; these sensors can be used alongside other technologies or types of sensors to provide feedback to users (eg, mobile apps).</p>
      </sec>
      <sec>
        <title>Objectives</title>
        <p>The aim of this review was to analyze the current uses and limitations of using inertial sensors for assessing movements during daily activities in individuals with hip or knee OA, including those who undergo joint replacement surgery, and to identify how this may translate to improved remote health care in this population. We conclude with a discussion highlighting the potential future applications and remaining areas where further development is required. This review may be used to inform current practices and further research on these promising technologies.</p>
      </sec>
    </sec>
    <sec sec-type="methods">
      <title>Methods</title>
      <sec>
        <title>Search Strategy</title>
        <p>For this narrative review, we performed an initial literature search in the PubMed and Embase databases in November 2018 and repeated the search in July 2019 and March 2021. The keywords used for the search were (“IMU” OR “inertial sensor” OR accelerometer OR gyroscope OR magnetometer OR wearable* OR sensor) AND (osteoarthritis OR arthritis OR “TKR” OR “TKA” OR “knee replacement” OR “knee arthroplasty”).</p>
      </sec>
      <sec>
        <title>Data Extraction</title>
        <p>We included studies that met the following criteria: (1) original studies published in the English language, (2) published within the previous 5 years, (3) used inertial sensors for the study of human movement, and (4) included data from people with OA or those with knee replacement. We excluded studies that used inertial sensors to study other related constructs (eg, sleep quality and physical activity) but did not directly study movement patterns. We excluded studies that focused on individuals with knee injuries without a diagnosis of knee OA (eg, anterior cruciate ligament tear and meniscus injury). Duplicate studies, systematic reviews, conference abstracts, and study protocols were also excluded. One researcher (either SE or MJR) screened the search result titles, removing studies that were not relevant to this review. For the remaining studies, 2 researchers (either SE and DK or MJR and KEC) read each study abstract to determine whether the study should be included. The final decision on inclusion was made in consensus by MJR, KEC, and DK. A total of 2 authors (SE and MJR) reviewed the included studies and annotated key information, including study objective, study population, details of the inertial sensor, specifics of the application for which the sensors were used, and the findings. After reviewing this information, we categorized the included studies based on the study objective to organize this review for the reader. Specifically, we categorized the studies into those related to the validity and repeatability of inertial sensor measurements (n=8), assessment of OA presence and severity (n=11), assessment of movement patterns associated with OA progression and gait retraining (n=7), assessment of OA intervention outcomes (n=14), and sensor placement and data analysis (n=3). For each of these sections, we synthesized the findings from the included studies with a focus on applications, limitations, challenges, and possible future directions. Tables are presented for each section, summarizing the key information from the included studies. Detailed descriptions of the study and sensor applications can be found in tables in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref> [<xref ref-type="bibr" rid="ref16">16</xref>-<xref ref-type="bibr" rid="ref56">56</xref>].</p>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Results</title>
      <p>Our literature search identified a total of 536 papers, of which 43 were determined relevant and included in this review (<xref rid="figure1" ref-type="fig">Figure 1</xref>).</p>
      <fig id="figure1" position="float">
        <label>Figure 1</label>
        <caption>
          <p>Literature search process.</p>
        </caption>
        <graphic xlink:href="rehab_v9i2e33521_fig1.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
      </fig>
      <sec>
        <title>Validity and Repeatability of Inertial Sensor Measurement of Movement</title>
        <p>As the use of wearable technology for movement quality assessment has increased, there is a need to assess the repeatability and validity of these technologies (<xref ref-type="table" rid="table1">Table 1</xref>; Table S1 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). In people with hip OA, waveforms recorded from a single pelvic IMU were reported to have a shape and magnitude similar to those recorded by optical motion capture [<xref ref-type="bibr" rid="ref57">57</xref>]. Using a robotic arm and anthropomorphic leg phantom to simulate knee flexion at 3 different speeds, Fennema et al [<xref ref-type="bibr" rid="ref16">16</xref>] identified acceptable test-retest repeatability of IMU-based joint angle measurements (&#60;+5° or −5°) across different knee flexion speeds or with repositioning of the IMUs. In healthy young adults, the foot progression angle (FPA), that is, the angle of the foot relative to the direction of travel, has also been measured with good to excellent validity (intraclass correlation coefficient=0.89-0.91) and reliability (intraclass correlation coefficient=0.95) [<xref ref-type="bibr" rid="ref17">17</xref>] and with errors &#60;2° compared with optical motion capture [<xref ref-type="bibr" rid="ref58">58</xref>] using a shoe-embedded IMU. Many IMU systems have been successfully validated against optical motion capture, including a 17-IMU system used to estimate knee adduction moment (KAM) and tibiofemoral joint contact forces [<xref ref-type="bibr" rid="ref18">18</xref>]; a 4-IMU system used to measure spatiotemporal gait variables and knee range of motion (ROM) [<xref ref-type="bibr" rid="ref19">19</xref>]; and a 7-IMU system used to measure ankle, knee, and hip joint angles in populations with hip [<xref ref-type="bibr" rid="ref20">20</xref>] and knee OA [<xref ref-type="bibr" rid="ref21">21</xref>]. In addition, Bravi et al [<xref ref-type="bibr" rid="ref22">22</xref>] found a single, lower trunk IMU valid for measuring spatiotemporal gait parameters in both healthy participants and patients with recent TKA or THA walking with crutches; however, the device struggled with gait cycle phase recognition in the patient group. Youn et al [<xref ref-type="bibr" rid="ref59">59</xref>] found that variables related to initial loading behavior (ie, knee flexion moment, KAM, anterior ground reaction force, and vertical ground reaction force) could be predicted (<italic>R</italic><sup>2</sup>≥0.60) from 10 temporal and kinetic parameters extracted from 2 ankle-worn accelerometers in patients post TKA. These studies suggest that wearable sensors can be used to estimate joint kinetics. IMU-based systems have also been found to provide valid metrics compared with optical motion capture during more demanding tasks (ie, stair ascent, stair descent, and sit-to-stand) in healthy older adults [<xref ref-type="bibr" rid="ref18">18</xref>] and during level walking in individuals post THA [<xref ref-type="bibr" rid="ref60">60</xref>]. Furthermore, low coefficient of variance values (&#60;10%) was reported when IMUs were placed by different operators or when sensors were displaced along the anteroposterior and mediolateral axes by +20 to −20 mm [<xref ref-type="bibr" rid="ref23">23</xref>]. As hardware enhancements continue and with the availability of larger data sets, it is anticipated that the performance of these devices will continue to improve, particularly with the use of advanced machine learning approaches for data analysis.</p>
        <table-wrap position="float" id="table1">
          <label>Table 1</label>
          <caption>
            <p>Inertial sensors validity and reliability measuring movement.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="140"/>
            <col width="240"/>
            <col width="270"/>
            <col width="350"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Population</td>
                <td>Sensor</td>
                <td>Findings</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Bravi et al, 2020 [<xref ref-type="bibr" rid="ref22">22</xref>]</td>
                <td>Healthy (n=10), THA<sup>a</sup> (n=10), and TKA<sup>b</sup> (n=10)</td>
                <td>Single IMU<sup>c</sup> (G-WALK, BTS Bioengineering) on trunk</td>
                <td>Single IMU reliable for measuring spatiotemporal gait in individuals using crutches</td>
              </tr>
              <tr valign="top">
                <td>Charlton et al, 2019 [<xref ref-type="bibr" rid="ref17">17</xref>]</td>
                <td>Healthy (n=20)</td>
                <td>Single IMU<sup>c</sup> (MPU-9150, InvenSense) embedded in shoe sole under heel</td>
                <td>Good to excellent reliability measuring foot progression angle in overground walking</td>
              </tr>
              <tr valign="top">
                <td>Fennema et al, 2019 [<xref ref-type="bibr" rid="ref16">16</xref>]</td>
                <td>Anthropomorphic phantom leg</td>
                <td>2 IMU<sup>c</sup> (MetaMotionR, mbientlab) on thigh and shank</td>
                <td>Acceptable repeatability in range of motion measurements from 2 different IMU placements</td>
              </tr>
              <tr valign="top">
                <td>Hafer et al, 2020 [<xref ref-type="bibr" rid="ref19">19</xref>]</td>
                <td>Healthy (n=20) and knee OA<sup>d</sup> (n=9)</td>
                <td>4 IMU<sup>c</sup> (OPAL, APDM) on foot, shank, thigh, and lower back</td>
                <td>Minimal IMU setup and reproducible methods can accurately capture gait metrics</td>
              </tr>
              <tr valign="top">
                <td>Ismailidis et al, 2020 [<xref ref-type="bibr" rid="ref20">20</xref>]</td>
                <td>Healthy (n=45) and hip OA (n=22)</td>
                <td>7 IMU<sup>c</sup> (RehaGait, Hasomed) on pelvis, feet, shanks, and thighs</td>
                <td>Validated commercial IMU system against literature on marker-based data differences between hip OA and healthy individuals</td>
              </tr>
              <tr valign="top">
                <td>Ismailidis et al, 2021 [<xref ref-type="bibr" rid="ref21">21</xref>]</td>
                <td>Healthy (n=46) and knee OA (n=22)</td>
                <td>7 IMU<sup>c</sup> (RehaGait) on pelvis, feet, shanks, and thighs</td>
                <td>Sensors able to discriminate between knee OA and healthy individuals and between affected and unaffected sides in unilateral knee OA</td>
              </tr>
              <tr valign="top">
                <td>Konrath et al, 2019 [<xref ref-type="bibr" rid="ref18">18</xref>]</td>
                <td>Healthy (n=8)</td>
                <td>17 IMU<sup>c</sup> (Xsens Awinda, Xsens Technologies BV) on entire body</td>
                <td>Moderate to strong Pearson correlation coefficients found between knee adduction moment and tibiofemoral joint contact force calculations</td>
              </tr>
              <tr valign="top">
                <td>Zügner et al, 2019 [<xref ref-type="bibr" rid="ref60">60</xref>]</td>
                <td>THA (n=49)</td>
                <td>6 IMU<sup>e</sup> (GaitSmart, Dynamic Metrics Ltd) on iliac crests, thighs, and shanks</td>
                <td>Validated IMUs for measuring mean pelvic tilt and knee flexion angles</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table1fn1">
              <p><sup>a</sup>THA: total hip arthroplasty.</p>
            </fn>
            <fn id="table1fn2">
              <p><sup>b</sup>TKA: total knee arthroplasty.</p>
            </fn>
            <fn id="table1fn3">
              <p><sup>c</sup>IMU: inertial measurement unit (with accelerometer, gyroscope, and magnetometer).</p>
            </fn>
            <fn id="table1fn4">
              <p><sup>d</sup>OA: osteoarthritis.</p>
            </fn>
            <fn id="table1fn5">
              <p><sup>e</sup>IMU with accelerometer and gyroscope.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
      </sec>
      <sec>
        <title>Assessment of OA Presence and Severity</title>
        <p>One of the most common applications of inertial sensors identified in this review was to determine the presence or severity of hip or knee OA using IMU-derived movement parameters (<xref ref-type="table" rid="table2">Table 2</xref>; Table S2 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). Across these studies, there was a wide variation in the methods used to extract various movement parameters. Simpler approaches rely on using raw sensor data and focus on walking gait. For instance, Tanimoto et al [<xref ref-type="bibr" rid="ref24">24</xref>] compared the peak shank angular velocity during swing directly measured from a gyroscope between people with knee OA and controls. The authors determined gait cycles using an acceleration signal. Although they did not find any significant differences in the average and variability measures of peak shank angular velocity between groups, they observed that greater angular velocity and lower variability of peak angular velocity were related to lower pain and better participant-reported function. Another relatively simple approach included using the mean and root mean square of the acceleration and angular velocity signals from foot-worn IMUs without undertaking any gait cycle detection [<xref ref-type="bibr" rid="ref23">23</xref>]. Using this approach, Barrois et al [<xref ref-type="bibr" rid="ref23">23</xref>] identified 4 of 61 parameters to be discriminative between people with knee or hip OA with moderate impairments, those with severe impairments, and healthy controls. However, given the large number of comparisons with a relatively small sample and no adjustment of the <italic>P</italic> value, their findings may be susceptible to type 1 errors. Finally, Na et al [<xref ref-type="bibr" rid="ref25">25</xref>] reported a greater magnitude of tibial acceleration and tibial jerk (ie, the time derivative of acceleration) during the midstance phase of walking in people with knee OA compared with controls and greater acceleration being related to greater self-reported knee instability. The findings from these studies suggest that information extracted from the raw acceleration or angular velocity signals, even from a single sensor, may be useful to discriminate between people with knee OA and controls and could be related to clinically meaningful participant-reported outcomes.</p>
        <table-wrap position="float" id="table2">
          <label>Table 2</label>
          <caption>
            <p>Inertial sensors and assessment of osteoarthritis presence and severity.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="170"/>
            <col width="170"/>
            <col width="280"/>
            <col width="380"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Population</td>
                <td>Sensor</td>
                <td>Findings</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Barrois et al, 2016 [<xref ref-type="bibr" rid="ref23">23</xref>]</td>
                <td> Healthy (n=12) and knee or hip OA<sup>a</sup> (n=48)</td>
                <td>4 IMU<sup>b</sup> (MTw, Xsens Technologies BV) on feet, lower back, and head</td>
                <td>Found discrimination capacity between OA severity groups in parameters of mean and root mean square of horizontal acceleration in both feet</td>
              </tr>
              <tr valign="top">
                <td>De Brabandere et al, 2020 [<xref ref-type="bibr" rid="ref31">31</xref>]</td>
                <td>Hip OA (n=20)</td>
                <td>Single IMU<sup>c</sup> (Samsung Galaxy J5 2017, Samsung) inside cell phone, attached to hip</td>
                <td>Trained machine learning pipeline to estimate hip and knee joint loading; error too large for clinical use</td>
              </tr>
              <tr valign="top">
                <td>Dindorf et al, 2020 [<xref ref-type="bibr" rid="ref32">32</xref>]</td>
                <td>Healthy (n=27) and THA<sup>d</sup> (n=20)</td>
                <td>7 IMU<sup>c</sup> (Awinda, Xsens Technologies BV) on feet, shanks, thighs, and back</td>
                <td>Automatically extracted features gave best machine learning accuracy in discriminating THA from healthy individuals</td>
              </tr>
              <tr valign="top">
                <td>Ismailidis et al, 2020 [<xref ref-type="bibr" rid="ref61">61</xref>]</td>
                <td>Healthy (n=48) and hip OA (n=24)</td>
                <td>7 IMU<sup>b</sup> (RehaGait, Hasomed) on pelvis, feet, shanks, and thighs</td>
                <td>Significant changes in hip and knee kinematics exist between hip OA and healthy individuals in speed matched conditions</td>
              </tr>
              <tr valign="top">
                <td>Ismailidis et al, 2020 [<xref ref-type="bibr" rid="ref26">26</xref>]</td>
                <td>Healthy (n=28) and knee OA (n=23)</td>
                <td>7 IMU<sup>b</sup> (RehaGait) on pelvis, feet, shanks, and thighs</td>
                <td>Significant differences in all spatiotemporal parameters between groups when walking at self-selected speed</td>
              </tr>
              <tr valign="top">
                <td>Na and Buchanan, 2021 [<xref ref-type="bibr" rid="ref25">25</xref>]</td>
                <td>Healthy (n=13) and knee OA (n=26)</td>
                <td>5 IMU<sup>c</sup> (3D myoMOTION, Noraxon) on pelvis, thighs, and shanks</td>
                <td>Linear acceleration (significant) and jerk (insignificant) negatively associated with self-reported instability</td>
              </tr>
              <tr valign="top">
                <td>Odonkor et al, 2020 [<xref ref-type="bibr" rid="ref27">27</xref>]</td>
                <td>Healthy (n=10) and knee OA (n=10)</td>
                <td>2 IMU<sup>b</sup> (Shimmer3, Shimmer Sensing) on feet</td>
                <td>Stance and double support ratio 2 most consistent discriminating features between OA and controls</td>
              </tr>
              <tr valign="top">
                <td>Tadano et al, 2016 [<xref ref-type="bibr" rid="ref28">28</xref>]</td>
                <td>Healthy (n=8) and knee OA (n=10)</td>
                <td>7 IMU<sup>c</sup> (H-Gait system, Laboratory of Biomechanical Design, Hokkaido University) on pelvis, thighs, shanks, and feet</td>
                <td>Angle between knee trajectories nearly twice as large in OA individuals compared with healthy controls</td>
              </tr>
              <tr valign="top">
                <td>Tanimoto et al, 2017 [<xref ref-type="bibr" rid="ref24">24</xref>]</td>
                <td>Healthy (n=11) and knee OA (n=12)</td>
                <td>Single IMU<sup>c</sup> (MVP-RF8-GC-500, Microstone) on anterior shank</td>
                <td>No differences between 2 groups for any parameters for peak shank angular velocity</td>
              </tr>
              <tr valign="top">
                <td>Van der Straaten et al, 2020 [<xref ref-type="bibr" rid="ref29">29</xref>]</td>
                <td>Healthy (n=12) and knee OA (n=19)</td>
                <td>15 IMU<sup>b</sup> (MVN BIOMECH Awinda) on entire body</td>
                <td>Individuals with knee OA walked with significantly less trunk rotation, less internal pelvic rotation during stance to swing, and reduced knee flexion among other discriminating differences</td>
              </tr>
              <tr valign="top">
                <td>Van der Straaten et al, 2020 [<xref ref-type="bibr" rid="ref30">30</xref>]</td>
                <td>Healthy (n=12) and knee OA (n=19)</td>
                <td>15 IMU<sup>b</sup> (MVN BIOMECH Awinda) on entire body</td>
                <td>Knee OA individuals had more lateral trunk lean toward contralateral leg and more hip flexion throughout performance of unipodal stance task</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table2fn1">
              <p><sup>a</sup>OA: osteoarthritis.</p>
            </fn>
            <fn id="table2fn2">
              <p><sup>b</sup>IMU: inertial measurement unit (with accelerometer, gyroscope, and magnetometer).</p>
            </fn>
            <fn id="table2fn3">
              <p><sup>c</sup>IMU with accelerometer and gyroscope.</p>
            </fn>
            <fn id="table2fn4">
              <p><sup>d</sup>THA: total hip arthroplasty.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <p>Other studies have used more computationally complex approaches to extract spatiotemporal parameters and joint kinematics during walking using IMU data. Ismailidis et al [<xref ref-type="bibr" rid="ref26">26</xref>,<xref ref-type="bibr" rid="ref61">61</xref>] published 2 studies, one each in people with end-stage hip OA and those with end-stage knee OA, in which they compared spatiotemporal and sagittal plane kinematics from IMUs between OA and control populations. Using statistical parametric mapping, they observed differences in multiple parameters (eg, cadence, knee, and hip kinematics) between each OA population and controls. Differences in spatiotemporal parameters between people with knee OA and controls [<xref ref-type="bibr" rid="ref27">27</xref>] and in joint kinematics among knees with varying OA severity [<xref ref-type="bibr" rid="ref28">28</xref>] have also been reported by other studies. These approaches are closer to the information traditionally obtained using 3D motion capture systems and allow for comparisons with existing literature. However, most of these studies relied on commercial systems, which raises concerns about the accuracy and validity of the data because the algorithms tend to be proprietary.</p>
        <p>In addition to walking, IMUs were used to compare movement patterns during other daily activities between individuals with OA and controls. In 2 studies from the same cohort of people with end-stage knee OA and controls, van der Straaten et al [<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref30">30</xref>] compared movement patterns during various activities, including walking, lunge, stair climbing, squatting, sit-to-stand, and single-leg balance. They reported differences in multiple measures, including those representing motions of the trunk and pelvis, which had not been previously reported. These authors also used a commercial system but undertook a validation study against optical motion capture. They concluded that the given IMU system was not ready for the assessment of movement patterns in patients with knee OA, particularly for motions in the frontal plane.</p>
        <p>The final 2 studies in this section used machine learning approaches during the postprocessing of IMU data [<xref ref-type="bibr" rid="ref31">31</xref>,<xref ref-type="bibr" rid="ref32">32</xref>]. Going beyond spatiotemporal parameters and joint kinematics, De Brabandere et al [<xref ref-type="bibr" rid="ref31">31</xref>] estimated hip and knee contact forces during various daily activities from a single IMU within a smartphone using machine learning. They observed differences in the model performance across joints (hip vs knee) and activities. They concluded that their approach, which was easy to use and promising in terms of model performance, did not result in an estimate of contact force that was sufficiently accurate for clinical use. However, this study represents an important advancement in the estimation of joint contact forces from IMUs, and future work with multiple sensors and more advanced machine learning approaches may yield better results. Finally, Dindorf et al [<xref ref-type="bibr" rid="ref32">32</xref>] used explainable artificial intelligence to classify people into those post total hip replacement and controls using data from 7 IMUs during walking. They used both raw data and joint kinematic data as inputs in different models and observed excellent model performance. They reported that sagittal movement of the hip, knee, and pelvis, along with transversal movement of the ankle, was especially important for classification [<xref ref-type="bibr" rid="ref32">32</xref>]. The use of machine learning and deep learning approaches is only expected to increase, particularly as IMUs facilitate the collection of data in cohorts much larger than is possible with traditional motion capture. These approaches could eventually lead to digital biomarkers of OA from data collected using simple and inexpensive IMU sensors.</p>
      </sec>
      <sec>
        <title>Assessment of Movement Parameters Related to OA Progression and Gait Retraining</title>
        <p>Although discriminating between people with and without OA is important, being able to identify individuals at risk of worsening disease early in the disease process would be even more valuable. To this end, another key application of inertial sensors was in using these relatively low-cost sensors to quantify important gait parameters that have previously been associated with knee OA progression (<xref ref-type="table" rid="table3">Table 3</xref>; Table S3 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>), such as varus thrust, KAM [<xref ref-type="bibr" rid="ref62">62</xref>,<xref ref-type="bibr" rid="ref63">63</xref>], and FPA [<xref ref-type="bibr" rid="ref64">64</xref>]. Capturing these parameters would traditionally require expensive 3D motion capture technologies, but inertial sensors may allow these risk factors to be captured with relative ease and at low cost in large samples.</p>
        <table-wrap position="float" id="table3">
          <label>Table 3</label>
          <caption>
            <p>Inertial sensors and assessment of movement patterns associated with osteoarthritis progression and gait retraining.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="140"/>
            <col width="160"/>
            <col width="270"/>
            <col width="430"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Population</td>
                <td>Sensor</td>
                <td>Findings</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Costello et al, 2020 [<xref ref-type="bibr" rid="ref33">33</xref>]</td>
                <td>Knee OA<sup>a</sup> (n=26)</td>
                <td>3 IMU<sup>b</sup> (Trigno IM Sensors, Delsys Inc) on thigh, midshank, and distal shank</td>
                <td>Single-leg sensor metrics were associated with surrogate measures of varus thrust, and midthigh adduction velocity was significantly associated with peak external knee adduction moment</td>
              </tr>
              <tr valign="top">
                <td>Ishii et al, 2020 [<xref ref-type="bibr" rid="ref34">34</xref>]</td>
                <td>Knee OA (n=44)</td>
                <td>2 IMU<sup>c</sup> (WAA-010, ATR-Promotions) placed on tibia and foot</td>
                <td>Positive correlation between lateral thrust and change in medial meniscus extrusion</td>
              </tr>
              <tr valign="top">
                <td>Iwama et al, 2021 [<xref ref-type="bibr" rid="ref35">35</xref>]</td>
                <td>Knee OA (n=22)</td>
                <td>6 IMU<sup>c</sup> (TSND151, ATR-Promotions) on pelvis, sternum, shanks, and thighs</td>
                <td>Moderate correlation found between acceleration peak in IMU frame and KAM, values from shank IMU had strongest correlation</td>
              </tr>
              <tr valign="top">
                <td>Karatsidis et al, 2018 [<xref ref-type="bibr" rid="ref38">38</xref>]</td>
                <td>Healthy (n=11)</td>
                <td>7 IMU<sup>b</sup> (MTw, Xsens Technologies BV) on pelvis, thighs, shanks, and feet</td>
                <td>High accuracy and repeatability of foot progression angle measures, and feedback effectiveness was similar between wearable and laboratory feedback setups</td>
              </tr>
              <tr valign="top">
                <td>Wang et al, 2020 [<xref ref-type="bibr" rid="ref36">36</xref>]</td>
                <td>Healthy (n=12), knee OA (n=78)</td>
                <td>2 IMU<sup>c</sup> (DA14583, Dialog Semiconductor) on malleoli</td>
                <td>Two machine learning algorithms were highly accurate (<italic>R</italic><sup>2</sup> approximately 0.95) in predicting KAM using IMU input</td>
              </tr>
              <tr valign="top">
                <td>Wouda et al, 2021 [<xref ref-type="bibr" rid="ref37">37</xref>]</td>
                <td>Healthy (n=5)</td>
                <td>2 IMU<sup>b</sup> (MTw Awinda, Xsens Technologies BV) on feet</td>
                <td>Good correlation coefficients to discriminate between different foot progression angle walking conditions</td>
              </tr>
              <tr valign="top">
                <td>Xia et al, 2020 [<xref ref-type="bibr" rid="ref39">39</xref>]</td>
                <td>Healthy (n=10)</td>
                <td>Single IMU<sup>b</sup> (custom-made) embedded in shoe sole</td>
                <td>Participants were able to respond to feedback during walking and adopt target foot progression angle conditions</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table3fn1">
              <p><sup>a</sup>OA: osteoarthritis.</p>
            </fn>
            <fn id="table3fn2">
              <p><sup>b</sup>IMU: inertial measurement unit (with accelerometer, gyroscope, and magnetometer).</p>
            </fn>
            <fn id="table3fn3">
              <p><sup>c</sup>IMU with accelerometer and gyroscope.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <p>Different sensor configurations during walking have been used to quantify varus thrust in gait; and one study using sensors on the thigh, midshank, and distal shank showed that midthigh sensor metrics were associated with optical motion capture thrust measurements while having less variability than midshank sensors [<xref ref-type="bibr" rid="ref33">33</xref>]. Another study using sensors on the tibial tubercles and dorsal surface of the foot found greater peak varus thrust in the severe OA group when compared with their early-stage OA group [<xref ref-type="bibr" rid="ref34">34</xref>]. Iwama et al [<xref ref-type="bibr" rid="ref35">35</xref>] assessed the correlation between peak KAM and peak-to-peak difference of acceleration in the medial-lateral axis using sensors on the sternum, pelvis, thighs, and shanks and found that the shank sensor had the highest correlation (<italic>R</italic>=0.57). Wang et al [<xref ref-type="bibr" rid="ref36">36</xref>] trained 2 machine learning algorithms using raw IMU data from sensors on the bilateral lateral malleoli to provide an accurate, real-time estimation of KAM during walking. The models—XGBoost and an artificial neural network—were trained to estimate KAM from a data set of both healthy individuals and those with knee OA, with both models having an <italic>R</italic><sup>2</sup> value of approximately 0.95 [<xref ref-type="bibr" rid="ref36">36</xref>]. Finally, single sensors on top of the shoes were used to estimate the FPA with a maximum mean error of approximately 2.6° [<xref ref-type="bibr" rid="ref37">37</xref>]. These approaches show promise for the use of wearables for accurate estimations of these important gait parameters in people with knee OA with the potential for gait retraining interventions that can directly target these parameters. However, further validation of these approaches in free-living conditions is required before they can be implemented in future interventions.</p>
        <p>Gait retraining to alter parameters related to OA progression is a natural follow-up to the aforementioned work. In knee OA, gait retraining typically aims to decrease the KAM [<xref ref-type="bibr" rid="ref36">36</xref>,<xref ref-type="bibr" rid="ref65">65</xref>,<xref ref-type="bibr" rid="ref66">66</xref>], a parameter linked to the severity and progression of knee OA [<xref ref-type="bibr" rid="ref67">67</xref>,<xref ref-type="bibr" rid="ref68">68</xref>]. Karatsidis et al [<xref ref-type="bibr" rid="ref38">38</xref>] used Microsoft HoloLens, an augmented reality headset, to provide feedback on FPA from 7 IMUs (on the pelvis, thighs, shanks, and feet) and found similar effectiveness between this approach and a laboratory approach (ie, projection screen in front of the participant) based on steps falling within a +2° to -2° targeted range. Furthermore, IMU-based FPA estimates closely matched those obtained from optical motion capture (overall root mean square difference of 2.38°) [<xref ref-type="bibr" rid="ref38">38</xref>]. Xia et al [<xref ref-type="bibr" rid="ref39">39</xref>] developed a shoe with an IMU-embedded insole and vibration motor to provide haptic feedback directly during walking to correct FPA, with participants successfully adopting 5 different FPA walking patterns after training. Although all these prior studies attempted to indirectly reduce KAM by altering other parameters (eg, FPA), some of the approaches discussed earlier that attempted to directly estimate KAM could potentially be used for gait retraining interventions in the future by adding feedback about this parameter [<xref ref-type="bibr" rid="ref35">35</xref>,<xref ref-type="bibr" rid="ref36">36</xref>].</p>
      </sec>
      <sec>
        <title>Assessment of OA Intervention Outcomes</title>
        <p>There has also been considerable interest in using wearable technology to remotely monitor data following interventions for OA (<xref ref-type="table" rid="table4">Table 4</xref>; Table S4 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). Lebleu et al [<xref ref-type="bibr" rid="ref40">40</xref>] used inertial sensors to track improvements in lower limb joint angles before and after administering a genicular nerve blockade in patients with knee OA and found a 9.3° increase in sagittal plane ROM during gait and a 3.3° decrease in pelvic transverse ROM when walking upstairs. In a novel application, Goślińska et al [<xref ref-type="bibr" rid="ref41">41</xref>] used IMUs to measure proprioception during physical therapy in patients with knee OA to assist in patient evaluation. Wearable sensors are used more often to monitor outcomes in patients undergoing joint replacement surgery. Hsieh et al [<xref ref-type="bibr" rid="ref42">42</xref>] used a 6-sensor system during the timed up and go test to identify subphases with this task using machine learning for patients with TKA; using preoperative and postoperative data, they achieved a classification accuracy of 92% for segmentation of subphases during the timed up and go test. Inertial sensors have also been used to identify remaining gait asymmetry following a 4-week rehabilitation program in individuals post THA [<xref ref-type="bibr" rid="ref69">69</xref>]. These studies demonstrate the potential of wearable technologies to monitor functional recovery after joint replacement surgeries in patients with knee or hip OA, potentially identifying individuals who may require additional rehabilitation or other medical care. When combined with patient factors (BMI, anesthesia status, and hemostatic use), data from wearables were used to identify associations between these factors and knee ROM post TKA [<xref ref-type="bibr" rid="ref43">43</xref>]. Thus, inertial sensors could be used not only to understand how interventions affect biomechanics or movement quality but also how patient factors are related to these outcomes.</p>
        <table-wrap position="float" id="table4">
          <label>Table 4</label>
          <caption>
            <p>Inertial sensors and assessment of osteoarthritis intervention outcomes.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="150"/>
            <col width="240"/>
            <col width="270"/>
            <col width="340"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Population</td>
                <td>Sensor</td>
                <td>Findings</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Bloomfield et al, 2021 [<xref ref-type="bibr" rid="ref51">51</xref>]</td>
                <td>TKA<sup>a</sup> (n=82)</td>
                <td>4 IMU<sup>b</sup> (MetaMotionR, MBientLab) on thighs and shanks</td>
                <td>Using only sensor data and no method of feature selection, random forest model was able to separate responders from maintainers with 93% accuracy</td>
              </tr>
              <tr valign="top">
                <td>Bloomfield et al, 2019 [<xref ref-type="bibr" rid="ref50">50</xref>]</td>
                <td>TKA (n=68)</td>
                <td>4 IMU<sup>b</sup> on thighs and shanks</td>
                <td>Successfully grouped patients using preoperative functional data into high function and low function short-term recovery groups</td>
              </tr>
              <tr valign="top">
                <td>Bolink et al, 2016 [<xref ref-type="bibr" rid="ref44">44</xref>]</td>
                <td>Healthy (n=30) and THA<sup>c</sup> (n=36)</td>
                <td>Single IMU<sup>d</sup> (Inertia-Link, MicroStrain) on posterior superior iliac spine</td>
                <td>Preoperative differences in gait parameters between low and high function groups disappeared by 3-month postoperative time point</td>
              </tr>
              <tr valign="top">
                <td>Chiang et al, 2017 [<xref ref-type="bibr" rid="ref43">43</xref>]</td>
                <td>TKA (n=18)</td>
                <td>2 IMU<sup>b</sup> (OPAL, APDM) on thigh and shank</td>
                <td>Different range of motion patterns present in patients that received different hemostatic agents shortly after surgery</td>
              </tr>
              <tr valign="top">
                <td>Di Benedetto et al, 2019 [<xref ref-type="bibr" rid="ref46">46</xref>]</td>
                <td>TKA (n=26)</td>
                <td>4 IMU<sup>b</sup> (Bioval, Movea)</td>
                <td>One TKA implant performed better in rotational flexion and freedom than other</td>
              </tr>
              <tr valign="top">
                <td>Goślińska et al, 2020 [<xref ref-type="bibr" rid="ref41">41</xref>]</td>
                <td>Healthy (n=27) and TKA (n=54)</td>
                <td>2 IMU<sup>b</sup> (Orthyo, Aisens) distal to both greater trochanter and tibial tuberosity</td>
                <td>No significantly impact of different rehabilitation programs on affected knee position sense in OA<sup>e</sup> groups</td>
              </tr>
              <tr valign="top">
                <td>Grip et al, 2019 [<xref ref-type="bibr" rid="ref47">47</xref>]</td>
                <td>Healthy (n=8), THA (n=15)</td>
                <td>5 IMU<sup>d</sup> (MoLab, AnyMo AB) on pelvis, thighs, and shanks</td>
                <td>Large femoral head THA surgery group had greater hip flexion range of motion than traditional THA surgery group</td>
              </tr>
              <tr valign="top">
                <td>Hsieh et al, 2020 [<xref ref-type="bibr" rid="ref42">42</xref>]</td>
                <td>THA (n=26)</td>
                <td>6 IMU<sup>d</sup> (OPAL) on chest, back, thighs, and shanks</td>
                <td>Accuracy &#62;90% in timed up and go subtask segmentation with AdaBoost machine learning technique</td>
              </tr>
              <tr valign="top">
                <td>Kluge et al, 2018 [<xref ref-type="bibr" rid="ref49">49</xref>]</td>
                <td>Healthy (n=24), TKA (n=24)</td>
                <td>2 IMU<sup>d</sup> (Shimmer3, Shimmer Sensing) on each foot</td>
                <td>Wearable-derived metrics consistent with previous literature on gait function in post-TKA populations</td>
              </tr>
              <tr valign="top">
                <td>Kobsar et al, 2017 [<xref ref-type="bibr" rid="ref52">52</xref>]</td>
                <td>Knee OA (n=39)</td>
                <td>4 IMU<sup>d</sup> (iNEMO inertial module, STMicroelectronics) on foot, shank, thigh, and back</td>
                <td>Sensor data were more accurate than patient-reported outcome measures in predicting response to hip strengthening program</td>
              </tr>
              <tr valign="top">
                <td>Kobsar, and Ferber, 2018 [<xref ref-type="bibr" rid="ref53">53</xref>]</td>
                <td>Knee OA (n=8)</td>
                <td>4 IMU<sup>d</sup> (iNEMO inertial module) on foot, shank, thigh, and back</td>
                <td>Average of 84 principal components needed to describe 95% of variance in gait patterns related to improvements in clinical outcomes</td>
              </tr>
              <tr valign="top">
                <td>Lebleu et al, 2020 [<xref ref-type="bibr" rid="ref40">40</xref>]</td>
                <td>Healthy (n=12), knee OA (n=14)</td>
                <td>7 IMU<sup>b</sup> (x-IMU, x-io Technologies) on waist, thighs shanks, and feet</td>
                <td>Cadence and stride time changed significantly after nerve blockade injections, tending toward values of healthy individuals</td>
              </tr>
              <tr valign="top">
                <td>Menz et al, 2016 [<xref ref-type="bibr" rid="ref48">48</xref>]</td>
                <td>First metatarsophalangeal OA (n=97)</td>
                <td>4 IMU<sup>d</sup> (LEGSys, Biosensics) on thighs and shanks</td>
                <td>Orthoses did not produce significant changes on spatiotemporal and kinematic parameters, rocker-sole reduced cadence to small effect and increased % stance time and reduced sagittal plane hip ROM to medium effect</td>
              </tr>
              <tr valign="top">
                <td>Shah et al, 2019 [<xref ref-type="bibr" rid="ref45">45</xref>]</td>
                <td>THA (n=10) and TKA (n=7)</td>
                <td>Single IMU<sup>b</sup> (Lumo Lift, Lumo Bodytech) on pelvis</td>
                <td>Raw data give better understanding than 24-hour summarized data for correlating with patient-reported outcome measures</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table4fn1">
              <p><sup>a</sup>TKA: total knee arthroplasty.</p>
            </fn>
            <fn id="table4fn2">
              <p><sup>b</sup>IMU: inertial measurement unit (with accelerometer, gyroscope, and magnetometer).</p>
            </fn>
            <fn id="table4fn3">
              <p><sup>c</sup>THA: total hip arthroplasty.</p>
            </fn>
            <fn id="table4fn4">
              <p><sup>d</sup>IMU unit with accelerometer and gyroscope.</p>
            </fn>
            <fn id="table4fn5">
              <p><sup>e</sup>OA: osteoarthritis.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <p>Wearable sensor data may provide information about recovery beyond that captured by the subjective measures of change. Bolink et al [<xref ref-type="bibr" rid="ref44">44</xref>] identified that objective gait parameters capture a dimension of physical function that is distinct from Western Ontario and McMaster Universities Arthritis Index scores in individuals post THA. Although Western Ontario and McMaster Universities Arthritis Index scores improved in patients with both low and high preoperative function at 3-month post THA, gait parameters only improved in those with low preoperative function [<xref ref-type="bibr" rid="ref44">44</xref>]. This finding that individuals with lower function have more functional improvement to gain from THA highlights the potential of inertial sensors to capture additional insights that are not clear from subjective data alone [<xref ref-type="bibr" rid="ref44">44</xref>]. Furthermore, Shah et al [<xref ref-type="bibr" rid="ref45">45</xref>] determined that increasing the sampling frequency of the sensor improves the accuracy of machine learning algorithms in predicting patient-reported outcomes.</p>
        <p>Wearable sensors have also been used to compare the outcomes of various OA treatments. Di Benedetto et al [<xref ref-type="bibr" rid="ref46">46</xref>] used a 4-IMU system (Bioval) to compare kinematic outcomes in patients who underwent TKA using different implants, finding a significant increase in knee flexion in one group. In addition, using sensors on the pelvis, thighs, and shanks, Grip et al [<xref ref-type="bibr" rid="ref47">47</xref>] found larger ROM during squats, gait, and stair ascent and descent in individuals receiving a THA implant with a larger femoral head than in those who received a conventional implant. IMUs have similarly been used to compare the effects of prefabricated foot orthoses and rocker-sole footwear on spatiotemporal parameters, hip and knee kinematics, and plantar pressure in individuals with OA of the first metatarsophalangeal joint [<xref ref-type="bibr" rid="ref48">48</xref>]. Using IMUs on the shanks, thighs, and lower back, along with plantar pressure insoles, Menz et al [<xref ref-type="bibr" rid="ref48">48</xref>] demonstrated that both interventions reduced the peak pressure beneath the first metatarsophalangeal joint and heel, but the rocker-sole footwear additionally reduced the pressure across the second through fifth metatarsophalangeal joints, whereas the orthoses increased the peak pressure under the lesser toes and midfoot. Although this study had a small sample relative to the number of comparisons, it highlights a novel application of wearable technology to study how interventions affect muscle force [<xref ref-type="bibr" rid="ref70">70</xref>]. In general, the studies discussed above highlight the potential of inertial sensors to provide objective outcomes in clinical trials with relative ease.</p>
        <p>With a heterogeneous OA population that may respond differently to interventions, an exciting area of development is in predicting the response to treatment. For example, high preoperative gait function assessed using 2 feet-worn IMUs was predictive of functional decreases post TKA, suggesting that those with lower preoperative function have more to gain [<xref ref-type="bibr" rid="ref49">49</xref>]. In addition, positive and negative responders can be predicted with an accuracy of up to 89% [<xref ref-type="bibr" rid="ref49">49</xref>]. Bloomfield et al [<xref ref-type="bibr" rid="ref50">50</xref>] used IMU data from sensors above and below the knee on participants during the timed up and go test preoperatively to group patients by functional improvement likelihood and to predict expected functional recovery after TKA [<xref ref-type="bibr" rid="ref51">51</xref>]. Similarly, Kobsar et al [<xref ref-type="bibr" rid="ref52">52</xref>] classified nonresponders, low responders, and high responders to a 6-week hip and core strengthening program for knee OA with 81.7% accuracy using preintervention data from IMUs on the lower back, thigh, shank, and foot, and similar results were obtained using a simplified 2-sensor system (thigh and back IMU data only). Furthermore, using a subsample of participants, Kobsar et al [<xref ref-type="bibr" rid="ref53">53</xref>] identified gait pattern changes that were associated with self-reported pain and function outcomes using a novel, subject-specific, machine learning approach, suggesting that machine learning analyses can be used with wearable sensor data in clinically meaningful ways.</p>
        <p>Most studies discussed in this section had small sample sizes with some being preliminary in nature. However, these studies demonstrated a wide range of possibilities with the use of wearable sensors to monitor intervention outcomes and predict responses to interventions.</p>
      </sec>
      <sec>
        <title>Sensor Placement and Data Analysis</title>
        <p>Given the variety of different parameters and sensor configurations used in studies using inertial sensors in populations with hip and knee OA or joint replacement, there has also been interested in investigating the effect of sensor configuration and data analysis on outcomes (<xref ref-type="table" rid="table5">Table 5</xref>; Table S5 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). For example, Sharifi et al [<xref ref-type="bibr" rid="ref54">54</xref>] used machine learning to analyze 15 combinations of data from a maximum 7-IMU system (feet, pelvis, shank, and thigh sensors) on individuals with OA and TKA to determine the optimal sensor combination to capture spatiotemporal gait parameters, with the feet-thigh combination having the best overall rank based on normalized absolute percentage error compared with the other sensor combinations. A few of the studies mentioned in this review also incorporated a comparison of different sensor locations into their work [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref35">35</xref>,<xref ref-type="bibr" rid="ref52">52</xref>], with the goal of optimizing the balance between convenience and patient burden (ie, low number of sensors) and valid data.</p>
        <table-wrap position="float" id="table5">
          <label>Table 5</label>
          <caption>
            <p>Inertial sensors sensor placement and data analysis.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="170"/>
            <col width="200"/>
            <col width="250"/>
            <col width="380"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Population</td>
                <td>Sensor</td>
                <td>Findings</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Boekesteijn et al, 2021 [<xref ref-type="bibr" rid="ref56">56</xref>]</td>
                <td>Healthy (n=27), knee OA<sup>a</sup> (n=25), and hip OA (n=26)</td>
                <td>4 IMU<sup>b</sup> (OPAL, APDM) on feet, lumbar spine, and sternum</td>
                <td>Stride length and cadence had strongest effect sizes for both OA groups during turning and dual-task performance during walking</td>
              </tr>
              <tr valign="top">
                <td>Sharifi et al, 2020 [<xref ref-type="bibr" rid="ref54">54</xref>]</td>
                <td>Knee OA (n=14) and TKA<sup>c</sup> (n=15)</td>
                <td>7 IMU<sup>d</sup> (Xsens Technologies BV) on pelvis, thighs, shanks, and feet</td>
                <td>Feet-thigh sensor combination identified as best for measuring spatiotemporal gait parameters</td>
              </tr>
              <tr valign="top">
                <td>Teufl et al, 2019 [<xref ref-type="bibr" rid="ref55">55</xref>]</td>
                <td>Healthy (n=24) and THA<sup>e</sup> (n=20)</td>
                <td>7 IMU<sup>b</sup> (Xsens Technologies BV) on pelvis, thighs, shanks, and feet</td>
                <td>Joint angles yielded 97% accuracy in differentiating gate between groups, spatiotemporal metrics gave 87.2% accuracy</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table5fn1">
              <p><sup>a</sup>OA: osteoarthritis.</p>
            </fn>
            <fn id="table5fn2">
              <p><sup>b</sup>IMU: inertial measurement unit (with accelerometer, gyroscope, and magnetometer).</p>
            </fn>
            <fn id="table5fn3">
              <p><sup>c</sup>TKA: total knee arthroplasty.</p>
            </fn>
            <fn id="table5fn4">
              <p><sup>d</sup>IMU with accelerometer and gyroscope.</p>
            </fn>
            <fn id="table5fn5">
              <p><sup>e</sup>THA: total hip arthroplasty.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <p>In addition to various sensor placement combinations, various methods for analyzing inertial sensor data have been explored. Teufl et al [<xref ref-type="bibr" rid="ref55">55</xref>] trained 2 different support vector machines—one using spatiotemporal gait parameters and one using joint angles, both from a 7-IMU system—to differentiate between impaired and nonimpaired gait using healthy controls and individuals post TKA. Both machines were successful (87.2% and 97.0% accuracy), and hip ROM symmetry was the most important single predictive feature, being roughly 3 times more important than the next feature, pelvic sagittal ROM [<xref ref-type="bibr" rid="ref55">55</xref>]. In a study of individuals with knee OA, hip OA, and healthy controls, Boekesteijn et al [<xref ref-type="bibr" rid="ref56">56</xref>] created 4 independent gait domains as a way to reduce the dimensionality of their data set and found the domains containing stride length, cadence, and lumbar sagittal ROM to be the most sensitive to detecting the presence of knee or hip OA. Other studies previously mentioned in this review (<xref ref-type="table" rid="table1">Tables 1</xref>-4) examined a variety of extracted metrics, with a few using machine learning for feature extraction or outcome prediction [<xref ref-type="bibr" rid="ref31">31</xref>,<xref ref-type="bibr" rid="ref32">32</xref>,<xref ref-type="bibr" rid="ref36">36</xref>,<xref ref-type="bibr" rid="ref51">51</xref>,<xref ref-type="bibr" rid="ref53">53</xref>]. These studies provide initial information about how sensor placement and data analysis affect outcomes; however, given the variety of factors used in the current literature, more work is needed in this area to identify the ideal sensor placements and extracted datatypes for specific applications of inertial sensors in lower limb OA.</p>
      </sec>
    </sec>
    <sec sec-type="discussion">
      <title>Discussion</title>
      <sec>
        <title>Principal Findings</title>
        <p>This review sought to examine the use of inertial sensors to assess the movement in the context of hip and knee OA clinical care in patients’ natural environments. We identified various applications of inertial sensors in hip and knee OA that have been published over the past 5 years, including assessment of OA presence and severity, assessment of and intervention on risk factors for OA progression, tracking intervention outcomes, and identifying individuals most likely to respond to interventions. Although further work is needed to validate the findings in real-world environments and determine optimal sensor placement and data analysis methods, the use of inertial sensors for these applications in hip and knee OA could improve opportunities for remote research and clinical care, particularly given the shifting health care landscape resulting from the COVID-19 pandemic [<xref ref-type="bibr" rid="ref71">71</xref>].</p>
      </sec>
      <sec>
        <title>Comparison With Prior Work</title>
        <p>There have been 2 previous reviews of wearable sensors in OA or postarthroplasty populations; however, these focused on very specific applications (gait analysis or postsurgical outcomes), whereas this review sought to assess all current and potential uses of inertial sensors in these populations. A scoping review by Kobsar et al [<xref ref-type="bibr" rid="ref72">72</xref>] on inertial sensors for gait analysis in individuals with OA identified multiple studies using inertial sensors for this application, with a range of sensor placements and outcomes used among the included studies. Although we similarly identified a range of sensor placements and outcome measures used in the studies included in this review, our results are based on the assessment by Kobsar et al [<xref ref-type="bibr" rid="ref72">72</xref>] regarding sensor protocols and outcome measures by examining the range of challenges and problems to which wearable sensors can and have been applied, including those beyond gait analysis. Importantly, both reviews identified the need to validate inertial sensor assessment of gait in free-living environments. Another review focused solely on wearable sensors in assessing functional outcome measures after lower extremity arthroplasty and found wearable sensors to be more sensitive than traditional functional outcome measures [<xref ref-type="bibr" rid="ref73">73</xref>]. Both this review and the current one suggest that more work is needed to understand the clinical relevance of sensor measures.</p>
        <p>Finally, we would like to recognize the timeliness of this review within the wider scope of the current research and global events. At the time of writing, the global COVID-19 pandemic is still ongoing [<xref ref-type="bibr" rid="ref74">74</xref>]. This event accelerated both the adoption of remote health care [<xref ref-type="bibr" rid="ref75">75</xref>] and the use of digital health technologies for the remote assessment of participants in clinical trials [<xref ref-type="bibr" rid="ref76">76</xref>]. By rerunning our literature search in March 2021, we were able to capture and include many studies using inertial sensors that were published during the first year of the pandemic. Of the 43 studies included in this review, 24 were published in either 2020 or the first 3 months of 2021. As the landscape of both data collection in general and the management of clinical trials moves outside of the laboratory with inertial sensors and wearable technology, we believe this review adds an important summary of new and current sensor applications to the existing body of literature.</p>
      </sec>
      <sec>
        <title>Limitations</title>
        <p>A number of limitations should be considered when interpreting the results of this review. First, although, in this study, we aimed to provide a narrative overview of the various applications of wearable inertial sensors for assessing movement quality in OA populations, the narrative format and change in search scope could have led to a selection bias in the studies included. To mitigate the risk of selection bias, 2 researchers (MJR and KEC) reviewed all identified abstracts from the final search strategy for potential inclusion and additionally reviewed studies selected for inclusion in the earlier searches to determine if they met the updated scope. Second, given the narrative format of this review, the quality of included studies was not assessed. Third, limiting the search to studies published within the past 5 years may have resulted in the exclusion of relevant studies published outside this range. This pragmatic choice was made owing to a significant increase in the number of publications on wearable sensors in recent years to present current results from this rapidly moving field. Fourth, the significant variability in sensor placement across the included studies limited our ability to draw conclusions regarding best practices for specific applications. Finally, this review does not address patients’ and clinicians’ perspectives on wearable technology. The reader is advised to consider stakeholder perspectives when implementing inertial sensors to assess movements in OA populations.</p>
      </sec>
      <sec>
        <title>Future Directions</title>
        <p>The results of this review highlight the potential of wearable sensors for remote monitoring of patients with OA and identification of those at risk for whom interventions may be needed. However, this work has primarily been done in relation to walking gait, with relatively few studies examining other types of movement (lunges, stair ascent and descent, squatting, sit-to-stand, and single-leg stance) [<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref31">31</xref>,<xref ref-type="bibr" rid="ref47">47</xref>] commonly experienced during everyday life. In addition, as described by Kobsar et al [<xref ref-type="bibr" rid="ref72">72</xref>] in a scoping review of inertial sensors for gait analysis in individuals with OA, more work is required in free-living environments. Given the low number of nongait studies and the high prevalence of laboratory-based data collection in the studies included in this review, further work is needed to validate whether inertial sensor data captured from various real-world activities are sensitive to disease initiation and risk of progression and thus could be used for remote monitoring and risk screening.</p>
        <p>In addition, we found only a handful of studies focused on training of movement patterns for individuals with OA, and of those we did identify, all focused on the feasibility and validation of gait retraining interventions. Questions remain around the large-scale deployment of inertial sensor—driven gait retraining or similar programs. The conclusions on the efficacy and acceptability of the interventions are of interest. Finally, although a few of the studies included in this review reported good reliability and validity of metrics extracted from inertial sensor data, a wide range of inertial sensor systems and extracted parameters were used in the various applications reviewed here. Continued research into optimal sensor placement to best capture relevant outcomes with minimum burden on the individual patient or participant may encourage the widespread use of these systems to capture biomechanical data in real-world settings.</p>
      </sec>
      <sec>
        <title>Conclusions</title>
        <p>Multiple opportunities exist to use inertial sensors to enhance remote health care for hip and knee OA. Within the last 5 years, research using inertial sensors in these populations has focused on the validity and repeatability of measurements, assessment of OA presence and severity, assessment of movement patterns associated with OA progression and gait retraining, assessment of OA intervention outcomes, and sensor placement and data analysis. Although these applications show great promise, further work is needed to investigate the use of inertial sensors in real-world settings, in a variety of activities of daily living, and in larger samples of individuals with hip and knee OA.</p>
      </sec>
    </sec>
  </body>
  <back>
    <app-group>
      <supplementary-material id="app1">
        <label>Multimedia Appendix 1</label>
        <p>Detailed tables on studies included in Results section of paper. Additional information given on study population (demographics data), sensor use and specifications, and application specifics.</p>
        <media xlink:href="rehab_v9i2e33521_app1.docx" xlink:title="DOCX File , 62 KB"/>
      </supplementary-material>
    </app-group>
    <glossary>
      <title>Abbreviations</title>
      <def-list>
        <def-item>
          <term id="abb1">FPA</term>
          <def>
            <p>foot progression angle</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb2">IMU</term>
          <def>
            <p>inertial measurement unit</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb3">KAM</term>
          <def>
            <p>knee adduction moment</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb4">OA</term>
          <def>
            <p>osteoarthritis</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb5">ROM</term>
          <def>
            <p>range of motion</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb6">THA</term>
          <def>
            <p>total hip arthroplasty</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb7">TKA</term>
          <def>
            <p>total knee arthroplasty</p>
          </def>
        </def-item>
      </def-list>
    </glossary>
    <ack>
      <p>The authors would like to thank the authors, whose work was included in this review. The research reported in this publication was supported by award numbers K01AR069720 (DK), T32AR007598 (KEC), and F32AR076907 (KEC) from the National Institutes of Health. The National Institutes of Health was not involved in the study design; collection, analysis, or interpretation of data; or the decision to submit this manuscript for publication.</p>
    </ack>
    <fn-group>
      <fn fn-type="con">
        <p>DK conceived of the study. MJR, KEC, SE, and DK selected journal articles to be included. All authors contributed to the synthesis and approval of the manuscript. DK takes responsibility for the integrity of the work.</p>
      </fn>
      <fn fn-type="conflict">
        <p>None declared.</p>
      </fn>
    </fn-group>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Wright</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Keith</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Wearable technology: if the tech fits, wear it</article-title>
          <source>J Electron Resources Medical Libraries</source>
          <year>2014</year>
          <month>12</month>
          <day>03</day>
          <volume>11</volume>
          <issue>4</issue>
          <fpage>204</fpage>
          <lpage>16</lpage>
          <pub-id pub-id-type="doi">10.1080/15424065.2014.969051</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Loeser</surname>
              <given-names>RF</given-names>
            </name>
            <name name-style="western">
              <surname>Goldring</surname>
              <given-names>SR</given-names>
            </name>
            <name name-style="western">
              <surname>Scanzello</surname>
              <given-names>CR</given-names>
            </name>
            <name name-style="western">
              <surname>Goldring</surname>
              <given-names>MB</given-names>
            </name>
          </person-group>
          <article-title>Osteoarthritis: a disease of the joint as an organ</article-title>
          <source>Arthritis Rheum</source>
          <year>2012</year>
          <month>06</month>
          <volume>64</volume>
          <issue>6</issue>
          <fpage>1697</fpage>
          <lpage>707</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://doi.org/10.1002/art.34453"/>
          </comment>
          <pub-id pub-id-type="doi">10.1002/art.34453</pub-id>
          <pub-id pub-id-type="medline">22392533</pub-id>
          <pub-id pub-id-type="pmcid">PMC3366018</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Guillemin</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Rat</surname>
              <given-names>AC</given-names>
            </name>
            <name name-style="western">
              <surname>Mazieres</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Pouchot</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Fautrel</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Euller-Ziegler</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Fardellone</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Morvan</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Roux</surname>
              <given-names>CH</given-names>
            </name>
            <name name-style="western">
              <surname>Verrouil</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Saraux</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Coste</surname>
              <given-names>J</given-names>
            </name>
            <collab>3000 Osteoarthritis group</collab>
          </person-group>
          <article-title>Prevalence of symptomatic hip and knee osteoarthritis: a two-phase population-based survey</article-title>
          <source>Osteoarthritis Cartilage</source>
          <year>2011</year>
          <month>11</month>
          <volume>19</volume>
          <issue>11</issue>
          <fpage>1314</fpage>
          <lpage>22</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://linkinghub.elsevier.com/retrieve/pii/S1063-4584(11)00235-4"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.joca.2011.08.004</pub-id>
          <pub-id pub-id-type="medline">21875676</pub-id>
          <pub-id pub-id-type="pii">S1063-4584(11)00235-4</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref4">
        <label>4</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Maradit Kremers</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Larson</surname>
              <given-names>DR</given-names>
            </name>
            <name name-style="western">
              <surname>Crowson</surname>
              <given-names>CS</given-names>
            </name>
            <name name-style="western">
              <surname>Kremers</surname>
              <given-names>WK</given-names>
            </name>
            <name name-style="western">
              <surname>Washington</surname>
              <given-names>RE</given-names>
            </name>
            <name name-style="western">
              <surname>Steiner</surname>
              <given-names>CA</given-names>
            </name>
            <name name-style="western">
              <surname>Jiranek</surname>
              <given-names>WA</given-names>
            </name>
            <name name-style="western">
              <surname>Berry</surname>
              <given-names>DJ</given-names>
            </name>
          </person-group>
          <article-title>Prevalence of total hip and knee replacement in the United States</article-title>
          <source>J Bone Joint Surg Am</source>
          <year>2015</year>
          <month>09</month>
          <day>02</day>
          <volume>97</volume>
          <issue>17</issue>
          <fpage>1386</fpage>
          <lpage>97</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/26333733"/>
          </comment>
          <pub-id pub-id-type="doi">10.2106/JBJS.N.01141</pub-id>
          <pub-id pub-id-type="medline">26333733</pub-id>
          <pub-id pub-id-type="pii">97/17/1386</pub-id>
          <pub-id pub-id-type="pmcid">PMC4551172</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref5">
        <label>5</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Griffin</surname>
              <given-names>TM</given-names>
            </name>
            <name name-style="western">
              <surname>Guilak</surname>
              <given-names>F</given-names>
            </name>
          </person-group>
          <article-title>The role of mechanical loading in the onset and progression of osteoarthritis</article-title>
          <source>Exerc Sport Sci Rev</source>
          <year>2005</year>
          <month>10</month>
          <volume>33</volume>
          <issue>4</issue>
          <fpage>195</fpage>
          <lpage>200</lpage>
          <pub-id pub-id-type="doi">10.1097/00003677-200510000-00008</pub-id>
          <pub-id pub-id-type="medline">16239837</pub-id>
          <pub-id pub-id-type="pii">00003677-200510000-00008</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref6">
        <label>6</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Reeves</surname>
              <given-names>ND</given-names>
            </name>
            <name name-style="western">
              <surname>Bowling</surname>
              <given-names>FL</given-names>
            </name>
          </person-group>
          <article-title>Conservative biomechanical strategies for knee osteoarthritis</article-title>
          <source>Nat Rev Rheumatol</source>
          <year>2011</year>
          <month>02</month>
          <volume>7</volume>
          <issue>2</issue>
          <fpage>113</fpage>
          <lpage>22</lpage>
          <pub-id pub-id-type="doi">10.1038/nrrheum.2010.212</pub-id>
          <pub-id pub-id-type="medline">21289615</pub-id>
          <pub-id pub-id-type="pii">nrrheum.2010.212</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref7">
        <label>7</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Brodie</surname>
              <given-names>MA</given-names>
            </name>
            <name name-style="western">
              <surname>Coppens</surname>
              <given-names>MJ</given-names>
            </name>
            <name name-style="western">
              <surname>Lord</surname>
              <given-names>SR</given-names>
            </name>
            <name name-style="western">
              <surname>Lovell</surname>
              <given-names>NH</given-names>
            </name>
            <name name-style="western">
              <surname>Gschwind</surname>
              <given-names>YJ</given-names>
            </name>
            <name name-style="western">
              <surname>Redmond</surname>
              <given-names>SJ</given-names>
            </name>
            <name name-style="western">
              <surname>Del Rosario</surname>
              <given-names>MB</given-names>
            </name>
            <name name-style="western">
              <surname>Wang</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Sturnieks</surname>
              <given-names>DL</given-names>
            </name>
            <name name-style="western">
              <surname>Persiani</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Delbaere</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
          <article-title>Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different</article-title>
          <source>Med Biol Eng Comput</source>
          <year>2016</year>
          <month>04</month>
          <volume>54</volume>
          <issue>4</issue>
          <fpage>663</fpage>
          <lpage>74</lpage>
          <pub-id pub-id-type="doi">10.1007/s11517-015-1357-9</pub-id>
          <pub-id pub-id-type="medline">26245255</pub-id>
          <pub-id pub-id-type="pii">10.1007/s11517-015-1357-9</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref8">
        <label>8</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Lukowicz</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Kirstein</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Tröster</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
          <article-title>Wearable systems for health care applications</article-title>
          <source>Methods Inf Med</source>
          <year>2004</year>
          <volume>43</volume>
          <issue>3</issue>
          <fpage>232</fpage>
          <lpage>8</lpage>
          <pub-id pub-id-type="medline">15227552</pub-id>
          <pub-id pub-id-type="pii">04030232</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref9">
        <label>9</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Dinesen</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Nøhr</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Andersen</surname>
              <given-names>SK</given-names>
            </name>
            <name name-style="western">
              <surname>Sejersen</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Toft</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
          <article-title>Under surveillance, yet looked after: telehomecare as viewed by patients and their spouse/partners</article-title>
          <source>Eur J Cardiovasc Nurs</source>
          <year>2008</year>
          <month>09</month>
          <volume>7</volume>
          <issue>3</issue>
          <fpage>239</fpage>
          <lpage>46</lpage>
          <pub-id pub-id-type="doi">10.1016/j.ejcnurse.2007.11.004</pub-id>
          <pub-id pub-id-type="medline">18230417</pub-id>
          <pub-id pub-id-type="pii">S1474-5151(07)00253-8</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref10">
        <label>10</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Mathie</surname>
              <given-names>MJ</given-names>
            </name>
            <name name-style="western">
              <surname>Coster</surname>
              <given-names>AC</given-names>
            </name>
            <name name-style="western">
              <surname>Lovell</surname>
              <given-names>NH</given-names>
            </name>
            <name name-style="western">
              <surname>Celler</surname>
              <given-names>BG</given-names>
            </name>
          </person-group>
          <article-title>Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement</article-title>
          <source>Physiol Meas</source>
          <year>2004</year>
          <month>04</month>
          <volume>25</volume>
          <issue>2</issue>
          <fpage>R1</fpage>
          <lpage>20</lpage>
          <pub-id pub-id-type="doi">10.1088/0967-3334/25/2/r01</pub-id>
          <pub-id pub-id-type="medline">15132305</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref11">
        <label>11</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Tong</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Granat</surname>
              <given-names>MH</given-names>
            </name>
          </person-group>
          <article-title>A practical gait analysis system using gyroscopes</article-title>
          <source>Med Eng Phys</source>
          <year>1999</year>
          <month>3</month>
          <volume>21</volume>
          <issue>2</issue>
          <fpage>87</fpage>
          <lpage>94</lpage>
          <pub-id pub-id-type="doi">10.1016/s1350-4533(99)00030-2</pub-id>
          <pub-id pub-id-type="medline">10426508</pub-id>
          <pub-id pub-id-type="pii">S1350453399000302</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref12">
        <label>12</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Rueterbories</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Spaich</surname>
              <given-names>EG</given-names>
            </name>
            <name name-style="western">
              <surname>Larsen</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Andersen</surname>
              <given-names>OK</given-names>
            </name>
          </person-group>
          <article-title>Methods for gait event detection and analysis in ambulatory systems</article-title>
          <source>Med Eng Phys</source>
          <year>2010</year>
          <month>07</month>
          <volume>32</volume>
          <issue>6</issue>
          <fpage>545</fpage>
          <lpage>52</lpage>
          <pub-id pub-id-type="doi">10.1016/j.medengphy.2010.03.007</pub-id>
          <pub-id pub-id-type="medline">20435502</pub-id>
          <pub-id pub-id-type="pii">S1350-4533(10)00071-8</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref13">
        <label>13</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Mayagoitia</surname>
              <given-names>RE</given-names>
            </name>
            <name name-style="western">
              <surname>Nene</surname>
              <given-names>AV</given-names>
            </name>
            <name name-style="western">
              <surname>Veltink</surname>
              <given-names>PH</given-names>
            </name>
          </person-group>
          <article-title>Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems</article-title>
          <source>J Biomech</source>
          <year>2002</year>
          <month>4</month>
          <volume>35</volume>
          <issue>4</issue>
          <fpage>537</fpage>
          <lpage>42</lpage>
          <pub-id pub-id-type="doi">10.1016/s0021-9290(01)00231-7</pub-id>
          <pub-id pub-id-type="medline">11934425</pub-id>
          <pub-id pub-id-type="pii">S0021929001002317</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref14">
        <label>14</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Dorsch</surname>
              <given-names>AK</given-names>
            </name>
            <name name-style="western">
              <surname>Thomas</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Xu</surname>
              <given-names>X</given-names>
            </name>
            <name name-style="western">
              <surname>Kaiser</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Dobkin</surname>
              <given-names>BH</given-names>
            </name>
            <collab>SIRRACT investigators</collab>
          </person-group>
          <article-title>SIRRACT: an international randomized clinical trial of activity feedback during inpatient stroke rehabilitation enabled by wireless sensing</article-title>
          <source>Neurorehabil Neural Repair</source>
          <year>2015</year>
          <month>06</month>
          <volume>29</volume>
          <issue>5</issue>
          <fpage>407</fpage>
          <lpage>15</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/25261154"/>
          </comment>
          <pub-id pub-id-type="doi">10.1177/1545968314550369</pub-id>
          <pub-id pub-id-type="medline">25261154</pub-id>
          <pub-id pub-id-type="pii">1545968314550369</pub-id>
          <pub-id pub-id-type="pmcid">PMC4375021</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref15">
        <label>15</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bonnet</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Héliot</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>A magnetometer-based approach for studying human movements</article-title>
          <source>IEEE Trans Biomed Eng</source>
          <year>2007</year>
          <month>07</month>
          <volume>54</volume>
          <issue>7</issue>
          <fpage>1353</fpage>
          <lpage>5</lpage>
          <pub-id pub-id-type="doi">10.1109/TBME.2007.890742</pub-id>
          <pub-id pub-id-type="medline">17605368</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref16">
        <label>16</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Fennema</surname>
              <given-names>MC</given-names>
            </name>
            <name name-style="western">
              <surname>Bloomfield</surname>
              <given-names>RA</given-names>
            </name>
            <name name-style="western">
              <surname>Lanting</surname>
              <given-names>BA</given-names>
            </name>
            <name name-style="western">
              <surname>Birmingham</surname>
              <given-names>TB</given-names>
            </name>
            <name name-style="western">
              <surname>Teeter</surname>
              <given-names>MG</given-names>
            </name>
          </person-group>
          <article-title>Repeatability of measuring knee flexion angles with wearable inertial sensors</article-title>
          <source>Knee</source>
          <year>2019</year>
          <month>01</month>
          <volume>26</volume>
          <issue>1</issue>
          <fpage>97</fpage>
          <lpage>105</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://linkinghub.elsevier.com/retrieve/pii/S0968-0160(18)30160-1"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.knee.2018.11.002</pub-id>
          <pub-id pub-id-type="medline">30554906</pub-id>
          <pub-id pub-id-type="pii">S0968-0160(18)30160-1</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref17">
        <label>17</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Charlton</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Xia</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Shull</surname>
              <given-names>PB</given-names>
            </name>
            <name name-style="western">
              <surname>Hunt</surname>
              <given-names>MA</given-names>
            </name>
          </person-group>
          <article-title>Validity and reliability of a shoe-embedded sensor module for measuring foot progression angle during over-ground walking</article-title>
          <source>J Biomech</source>
          <year>2019</year>
          <month>05</month>
          <day>24</day>
          <volume>89</volume>
          <fpage>123</fpage>
          <lpage>7</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2019.04.012</pub-id>
          <pub-id pub-id-type="medline">31047695</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(19)30276-3</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref18">
        <label>18</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Konrath</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Karatsidis</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Schepers</surname>
              <given-names>HM</given-names>
            </name>
            <name name-style="western">
              <surname>Bellusci</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>de Zee</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Andersen</surname>
              <given-names>MS</given-names>
            </name>
          </person-group>
          <article-title>Estimation of the knee adduction moment and joint contact force during daily living activities using inertial motion capture</article-title>
          <source>Sensors (Basel)</source>
          <year>2019</year>
          <month>04</month>
          <day>09</day>
          <volume>19</volume>
          <issue>7</issue>
          <fpage>1681</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s19071681"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s19071681</pub-id>
          <pub-id pub-id-type="medline">30970538</pub-id>
          <pub-id pub-id-type="pii">s19071681</pub-id>
          <pub-id pub-id-type="pmcid">PMC6480627</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref19">
        <label>19</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Hafer</surname>
              <given-names>JF</given-names>
            </name>
            <name name-style="western">
              <surname>Provenzano</surname>
              <given-names>SG</given-names>
            </name>
            <name name-style="western">
              <surname>Kern</surname>
              <given-names>KL</given-names>
            </name>
            <name name-style="western">
              <surname>Agresta</surname>
              <given-names>CE</given-names>
            </name>
            <name name-style="western">
              <surname>Grant</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>Zernicke</surname>
              <given-names>RF</given-names>
            </name>
          </person-group>
          <article-title>Measuring markers of aging and knee osteoarthritis gait using inertial measurement units</article-title>
          <source>J Biomech</source>
          <year>2020</year>
          <month>01</month>
          <day>23</day>
          <volume>99</volume>
          <fpage>109567</fpage>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2019.109567</pub-id>
          <pub-id pub-id-type="medline">31916999</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(19)30830-9</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref20">
        <label>20</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ismailidis</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Nüesch</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Kaufmann</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Clauss</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Pagenstert</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Eckardt</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ilchmann</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Mündermann</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Measuring gait kinematics in patients with severe hip osteoarthritis using wearable sensors</article-title>
          <source>Gait Posture</source>
          <year>2020</year>
          <month>09</month>
          <volume>81</volume>
          <fpage>49</fpage>
          <lpage>55</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2020.07.004</pub-id>
          <pub-id pub-id-type="medline">32679463</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(20)30237-X</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref21">
        <label>21</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ismailidis</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Hegglin</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Egloff</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Pagenstert</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Kernen</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Eckardt</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ilchmann</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Nüesch</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Mündermann</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Side to side kinematic gait differences within patients and spatiotemporal and kinematic gait differences between patients with severe knee osteoarthritis and controls measured with inertial sensors</article-title>
          <source>Gait Posture</source>
          <year>2021</year>
          <month>02</month>
          <volume>84</volume>
          <fpage>24</fpage>
          <lpage>30</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2020.11.015</pub-id>
          <pub-id pub-id-type="medline">33260078</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(20)30640-8</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref22">
        <label>22</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bravi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Gallotta</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Morrone</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Maselli</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Santacaterina</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Toglia</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Foti</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Sterzi</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Bressi</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Miccinilli</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Concurrent validity and inter trial reliability of a single inertial measurement unit for spatial-temporal gait parameter analysis in patients with recent total hip or total knee arthroplasty</article-title>
          <source>Gait Posture</source>
          <year>2020</year>
          <month>02</month>
          <volume>76</volume>
          <fpage>175</fpage>
          <lpage>81</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2019.12.014</pub-id>
          <pub-id pub-id-type="medline">31862666</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(19)31783-7</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref23">
        <label>23</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Barrois</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Gregory</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Oudre</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Moreau</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Truong</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Aram Pulini</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Vienne</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Labourdette</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Vayatis</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Buffat</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Yelnik</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Waele</surname>
              <given-names>CD</given-names>
            </name>
            <name name-style="western">
              <surname>Laporte</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Vidal</surname>
              <given-names>PP</given-names>
            </name>
            <name name-style="western">
              <surname>Ricard</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
          <article-title>An automated recording method in clinical consultation to rate the limp in lower limb osteoarthritis</article-title>
          <source>PLoS One</source>
          <year>2016</year>
          <volume>11</volume>
          <issue>10</issue>
          <fpage>e0164975</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://dx.plos.org/10.1371/journal.pone.0164975"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0164975</pub-id>
          <pub-id pub-id-type="medline">27776168</pub-id>
          <pub-id pub-id-type="pii">PONE-D-15-43758</pub-id>
          <pub-id pub-id-type="pmcid">PMC5077168</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref24">
        <label>24</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Tanimoto</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Takahashi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Tokuda</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Sawada</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Anan</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Shinkoda</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
          <article-title>Lower limb kinematics during the swing phase in patients with knee osteoarthritis measured using an inertial sensor</article-title>
          <source>Gait Posture</source>
          <year>2017</year>
          <month>09</month>
          <volume>57</volume>
          <fpage>236</fpage>
          <lpage>40</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2017.06.017</pub-id>
          <pub-id pub-id-type="medline">28668737</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(17)30240-0</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref25">
        <label>25</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Na</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Buchanan</surname>
              <given-names>TS</given-names>
            </name>
          </person-group>
          <article-title>Validating wearable sensors using self-reported instability among patients with knee osteoarthritis</article-title>
          <source>PM R</source>
          <year>2021</year>
          <month>02</month>
          <volume>13</volume>
          <issue>2</issue>
          <fpage>119</fpage>
          <lpage>27</lpage>
          <pub-id pub-id-type="doi">10.1002/pmrj.12393</pub-id>
          <pub-id pub-id-type="medline">32358908</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref26">
        <label>26</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ismailidis</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Egloff</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Hegglin</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Pagenstert</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Kernen</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Eckardt</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ilchmann</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Mündermann</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Nüesch</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Kinematic changes in patients with severe knee osteoarthritis are a result of reduced walking speed rather than disease severity</article-title>
          <source>Gait Posture</source>
          <year>2020</year>
          <month>06</month>
          <volume>79</volume>
          <fpage>256</fpage>
          <lpage>61</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2020.05.008</pub-id>
          <pub-id pub-id-type="medline">32460135</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(20)30157-0</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref27">
        <label>27</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Odonkor</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Kuwabara</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Tomkins-Lane</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Zhang</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Muaremi</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Leutheuser</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Sun</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Smuck</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Gait features for discriminating between mobility-limiting musculoskeletal disorders: lumbar spinal stenosis and knee osteoarthritis</article-title>
          <source>Gait Posture</source>
          <year>2020</year>
          <month>07</month>
          <volume>80</volume>
          <fpage>96</fpage>
          <lpage>100</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2020.05.019</pub-id>
          <pub-id pub-id-type="medline">32497982</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(20)30169-7</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref28">
        <label>28</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Tadano</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Takeda</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Sasaki</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Fujisawa</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Tohyama</surname>
              <given-names>H</given-names>
            </name>
          </person-group>
          <article-title>Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems)</article-title>
          <source>J Biomech</source>
          <year>2016</year>
          <month>03</month>
          <day>21</day>
          <volume>49</volume>
          <issue>5</issue>
          <fpage>684</fpage>
          <lpage>90</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2016.01.017</pub-id>
          <pub-id pub-id-type="medline">26947036</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(16)30021-5</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref29">
        <label>29</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>van der Straaten</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Wesseling</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Jonkers</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Vanwanseele</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Bruijnes</surname>
              <given-names>AK</given-names>
            </name>
            <name name-style="western">
              <surname>Malcorps</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Bellemans</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Truijen</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>De Baets</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Timmermans</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Functional movement assessment by means of inertial sensor technology to discriminate between movement behaviour of healthy controls and persons with knee osteoarthritis</article-title>
          <source>J Neuroeng Rehabil</source>
          <year>2020</year>
          <month>05</month>
          <day>19</day>
          <volume>17</volume>
          <issue>1</issue>
          <fpage>65</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-020-00694-2"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12984-020-00694-2</pub-id>
          <pub-id pub-id-type="medline">32430036</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12984-020-00694-2</pub-id>
          <pub-id pub-id-type="pmcid">PMC7236325</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref30">
        <label>30</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>van der Straaten</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Wesseling</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Jonkers</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Vanwanseele</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Bruijnes</surname>
              <given-names>AK</given-names>
            </name>
            <name name-style="western">
              <surname>Malcorps</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Bellemans</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Truijen</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>De Baets</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Timmermans</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Discriminant validity of 3D joint kinematics and centre of mass displacement measured by inertial sensor technology during the unipodal stance task</article-title>
          <source>PLoS One</source>
          <year>2020</year>
          <volume>15</volume>
          <issue>5</issue>
          <fpage>e0232513</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://dx.plos.org/10.1371/journal.pone.0232513"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0232513</pub-id>
          <pub-id pub-id-type="medline">32407415</pub-id>
          <pub-id pub-id-type="pii">PONE-D-19-17344</pub-id>
          <pub-id pub-id-type="pmcid">PMC7224481</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref31">
        <label>31</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>De Brabandere</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Emmerzaal</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Timmermans</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Jonkers</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Vanwanseele</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Davis</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>A machine learning approach to estimate hip and knee joint loading using a mobile phone-embedded IMU</article-title>
          <source>Front Bioeng Biotechnol</source>
          <year>2020</year>
          <volume>8</volume>
          <fpage>320</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://doi.org/10.3389/fbioe.2020.00320"/>
          </comment>
          <pub-id pub-id-type="doi">10.3389/fbioe.2020.00320</pub-id>
          <pub-id pub-id-type="medline">32351952</pub-id>
          <pub-id pub-id-type="pmcid">PMC7174587</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref32">
        <label>32</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Dindorf</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Teufl</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Taetz</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Bleser</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Fröhlich</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Interpretability of input representations for gait classification in patients after total hip arthroplasty</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <month>08</month>
          <day>06</day>
          <volume>20</volume>
          <issue>16</issue>
          <fpage>4385</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20164385"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20164385</pub-id>
          <pub-id pub-id-type="medline">32781583</pub-id>
          <pub-id pub-id-type="pii">s20164385</pub-id>
          <pub-id pub-id-type="pmcid">PMC7471970</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref33">
        <label>33</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Costello</surname>
              <given-names>KE</given-names>
            </name>
            <name name-style="western">
              <surname>Eigenbrot</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Geronimo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Guermazi</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Felson</surname>
              <given-names>DT</given-names>
            </name>
            <name name-style="western">
              <surname>Richards</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Kumar</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
          <article-title>Quantifying varus thrust in knee osteoarthritis using wearable inertial sensors: a proof of concept</article-title>
          <source>Clin Biomech (Bristol, Avon)</source>
          <year>2020</year>
          <month>12</month>
          <volume>80</volume>
          <fpage>105232</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/33202314"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2020.105232</pub-id>
          <pub-id pub-id-type="medline">33202314</pub-id>
          <pub-id pub-id-type="pii">S0268-0033(20)30351-X</pub-id>
          <pub-id pub-id-type="pmcid">PMC7749075</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref34">
        <label>34</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ishii</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Ishikawa</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Kurumadani</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Hayashi</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Nakamae</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Nakasa</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Sumida</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Tsuyuguchi</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Kanemitsu</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Deie</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Adachi</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Sunagawa</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Increase in medial meniscal extrusion in the weight-bearing position observed on ultrasonography correlates with lateral thrust in early-stage knee osteoarthritis</article-title>
          <source>J Orthop Sci</source>
          <year>2020</year>
          <month>07</month>
          <volume>25</volume>
          <issue>4</issue>
          <fpage>640</fpage>
          <lpage>6</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jos.2019.07.003</pub-id>
          <pub-id pub-id-type="medline">31350063</pub-id>
          <pub-id pub-id-type="pii">S0949-2658(19)30205-2</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref35">
        <label>35</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Iwama</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Harato</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Kobayashi</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Niki</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Ogihara</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Matsumoto</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Nakamura</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Nagura</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Estimation of the external knee adduction moment during gait using an inertial measurement unit in patients with knee osteoarthritis</article-title>
          <source>Sensors (Basel)</source>
          <year>2021</year>
          <month>02</month>
          <day>18</day>
          <volume>21</volume>
          <issue>4</issue>
          <fpage>1418</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s21041418"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s21041418</pub-id>
          <pub-id pub-id-type="medline">33670561</pub-id>
          <pub-id pub-id-type="pii">s21041418</pub-id>
          <pub-id pub-id-type="pmcid">PMC7922156</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref36">
        <label>36</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Wang</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Chan</surname>
              <given-names>PP</given-names>
            </name>
            <name name-style="western">
              <surname>Lam</surname>
              <given-names>BM</given-names>
            </name>
            <name name-style="western">
              <surname>Wang</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Zhang</surname>
              <given-names>JH</given-names>
            </name>
            <name name-style="western">
              <surname>Chan</surname>
              <given-names>ZY</given-names>
            </name>
            <name name-style="western">
              <surname>Chan</surname>
              <given-names>RH</given-names>
            </name>
            <name name-style="western">
              <surname>Ho</surname>
              <given-names>KK</given-names>
            </name>
            <name name-style="western">
              <surname>Cheung</surname>
              <given-names>RT</given-names>
            </name>
          </person-group>
          <article-title>Real-time estimation of knee adduction moment for gait retraining in patients with knee osteoarthritis</article-title>
          <source>IEEE Trans Neural Syst Rehabil Eng</source>
          <year>2020</year>
          <month>04</month>
          <volume>28</volume>
          <issue>4</issue>
          <fpage>888</fpage>
          <lpage>94</lpage>
          <pub-id pub-id-type="doi">10.1109/TNSRE.2020.2978537</pub-id>
          <pub-id pub-id-type="medline">32149643</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref37">
        <label>37</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Wouda</surname>
              <given-names>FJ</given-names>
            </name>
            <name name-style="western">
              <surname>Jaspar</surname>
              <given-names>SL</given-names>
            </name>
            <name name-style="western">
              <surname>Harlaar</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>van Beijnum</surname>
              <given-names>BF</given-names>
            </name>
            <name name-style="western">
              <surname>Veltink</surname>
              <given-names>PH</given-names>
            </name>
          </person-group>
          <article-title>Foot progression angle estimation using a single foot-worn inertial sensor</article-title>
          <source>J Neuroeng Rehabil</source>
          <year>2021</year>
          <month>02</month>
          <day>17</day>
          <volume>18</volume>
          <issue>1</issue>
          <fpage>37</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-021-00816-4"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12984-021-00816-4</pub-id>
          <pub-id pub-id-type="medline">33596942</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12984-021-00816-4</pub-id>
          <pub-id pub-id-type="pmcid">PMC7888122</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref38">
        <label>38</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Karatsidis</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Richards</surname>
              <given-names>RE</given-names>
            </name>
            <name name-style="western">
              <surname>Konrath</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>van den Noort</surname>
              <given-names>JC</given-names>
            </name>
            <name name-style="western">
              <surname>Schepers</surname>
              <given-names>HM</given-names>
            </name>
            <name name-style="western">
              <surname>Bellusci</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Harlaar</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Veltink</surname>
              <given-names>PH</given-names>
            </name>
          </person-group>
          <article-title>Validation of wearable visual feedback for retraining foot progression angle using inertial sensors and an augmented reality headset</article-title>
          <source>J Neuroeng Rehabil</source>
          <year>2018</year>
          <month>08</month>
          <day>15</day>
          <volume>15</volume>
          <issue>1</issue>
          <fpage>78</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-018-0419-2"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12984-018-0419-2</pub-id>
          <pub-id pub-id-type="medline">30111337</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12984-018-0419-2</pub-id>
          <pub-id pub-id-type="pmcid">PMC6094564</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref39">
        <label>39</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Xia</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Charlton</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Shull</surname>
              <given-names>PB</given-names>
            </name>
            <name name-style="western">
              <surname>Hunt</surname>
              <given-names>MA</given-names>
            </name>
          </person-group>
          <article-title>Portable, automated foot progression angle gait modification via a proof-of-concept haptic feedback-sensorized shoe</article-title>
          <source>J Biomech</source>
          <year>2020</year>
          <month>06</month>
          <day>23</day>
          <volume>107</volume>
          <fpage>109789</fpage>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2020.109789</pub-id>
          <pub-id pub-id-type="medline">32321637</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(20)30209-8</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref40">
        <label>40</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Lebleu</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Fonkoue</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Bandolo</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Fossoh</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Mahaudens</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Cornu</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Detrembleur</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Lower limb kinematics improvement after genicular nerve blockade in patients with knee osteoarthritis: a milestone study using inertial sensors</article-title>
          <source>BMC Musculoskelet Disord</source>
          <year>2020</year>
          <month>12</month>
          <day>07</day>
          <volume>21</volume>
          <issue>1</issue>
          <fpage>822</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcmusculoskeletdisord.biomedcentral.com/articles/10.1186/s12891-020-03836-8"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12891-020-03836-8</pub-id>
          <pub-id pub-id-type="medline">33287783</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12891-020-03836-8</pub-id>
          <pub-id pub-id-type="pmcid">PMC7722305</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref41">
        <label>41</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Goślińska</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Wareńczak</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Miedzyblocki</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Hejdysz</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Adamczyk</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Sip</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Chlebuś</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Gośliński</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Owczarek</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Woźniak</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Lisiński</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
          <article-title>Wireless motion sensors-useful in assessing the effectiveness of physiotherapeutic methods used in patients with knee osteoarthritis-preliminary report</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <month>04</month>
          <day>16</day>
          <volume>20</volume>
          <issue>8</issue>
          <fpage>2268</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20082268"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20082268</pub-id>
          <pub-id pub-id-type="medline">32316331</pub-id>
          <pub-id pub-id-type="pii">s20082268</pub-id>
          <pub-id pub-id-type="pmcid">PMC7219042</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref42">
        <label>42</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Hsieh</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Huang</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Liu</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Hsu</surname>
              <given-names>SJ</given-names>
            </name>
            <name name-style="western">
              <surname>Chan</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Subtask segmentation of timed up and go test for mobility assessment of perioperative total knee arthroplasty</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <month>11</month>
          <day>05</day>
          <volume>20</volume>
          <issue>21</issue>
          <fpage>6302</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20216302"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20216302</pub-id>
          <pub-id pub-id-type="medline">33167444</pub-id>
          <pub-id pub-id-type="pii">s20216302</pub-id>
          <pub-id pub-id-type="pmcid">PMC7663910</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref43">
        <label>43</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Chiang</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Liu</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Hsu</surname>
              <given-names>SJ</given-names>
            </name>
            <name name-style="western">
              <surname>Chan</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Data collection and analysis using wearable sensors for monitoring knee range of motion after total knee arthroplasty</article-title>
          <source>Sensors (Basel)</source>
          <year>2017</year>
          <month>02</month>
          <day>22</day>
          <volume>17</volume>
          <issue>2</issue>
          <fpage>418</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s17020418"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s17020418</pub-id>
          <pub-id pub-id-type="medline">28241434</pub-id>
          <pub-id pub-id-type="pii">s17020418</pub-id>
          <pub-id pub-id-type="pmcid">PMC5336055</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref44">
        <label>44</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bolink</surname>
              <given-names>SA</given-names>
            </name>
            <name name-style="western">
              <surname>Lenguerrand</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Brunton</surname>
              <given-names>LR</given-names>
            </name>
            <name name-style="western">
              <surname>Wylde</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Gooberman-Hill</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Heyligers</surname>
              <given-names>IC</given-names>
            </name>
            <name name-style="western">
              <surname>Blom</surname>
              <given-names>AW</given-names>
            </name>
            <name name-style="western">
              <surname>Grimm</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Assessment of physical function following total hip arthroplasty: inertial sensor based gait analysis is supplementary to patient-reported outcome measures</article-title>
          <source>Clin Biomech (Bristol, Avon)</source>
          <year>2016</year>
          <month>02</month>
          <volume>32</volume>
          <fpage>171</fpage>
          <lpage>9</lpage>
          <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2015.11.014</pub-id>
          <pub-id pub-id-type="medline">26706048</pub-id>
          <pub-id pub-id-type="pii">S0268-0033(15)00316-2</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref45">
        <label>45</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Shah</surname>
              <given-names>RF</given-names>
            </name>
            <name name-style="western">
              <surname>Zaid</surname>
              <given-names>MB</given-names>
            </name>
            <name name-style="western">
              <surname>Bendich</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Hwang</surname>
              <given-names>KM</given-names>
            </name>
            <name name-style="western">
              <surname>Patterson</surname>
              <given-names>JT</given-names>
            </name>
            <name name-style="western">
              <surname>Bini</surname>
              <given-names>SA</given-names>
            </name>
          </person-group>
          <article-title>Optimal sampling frequency for wearable sensor data in arthroplasty outcomes research. A prospective observational cohort trial</article-title>
          <source>J Arthroplasty</source>
          <year>2019</year>
          <month>10</month>
          <volume>34</volume>
          <issue>10</issue>
          <fpage>2248</fpage>
          <lpage>52</lpage>
          <pub-id pub-id-type="doi">10.1016/j.arth.2019.08.001</pub-id>
          <pub-id pub-id-type="medline">31445866</pub-id>
          <pub-id pub-id-type="pii">S0883-5403(19)30732-6</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref46">
        <label>46</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Di Benedetto</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Vidi</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Colombo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Buttironi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Cainero</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Causero</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Pre-operative and post-operative kinematic analysis in total knee arthroplasty. A pilot study</article-title>
          <source>Acta Biomed</source>
          <year>2019</year>
          <month>12</month>
          <day>05</day>
          <volume>90</volume>
          <issue>12-S</issue>
          <fpage>91</fpage>
          <lpage>7</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/31821291"/>
          </comment>
          <pub-id pub-id-type="doi">10.23750/abm.v90i12-S.8984</pub-id>
          <pub-id pub-id-type="medline">31821291</pub-id>
          <pub-id pub-id-type="pmcid">PMC7233708</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref47">
        <label>47</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Grip</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Nilsson</surname>
              <given-names>KG</given-names>
            </name>
            <name name-style="western">
              <surname>Häger</surname>
              <given-names>CK</given-names>
            </name>
            <name name-style="western">
              <surname>Lundström</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Öhberg</surname>
              <given-names>F</given-names>
            </name>
          </person-group>
          <article-title>Does the femoral head size in hip arthroplasty influence lower body movements during squats, gait and stair walking? A clinical pilot study based on wearable motion sensors</article-title>
          <source>Sensors (Basel)</source>
          <year>2019</year>
          <month>07</month>
          <day>23</day>
          <volume>19</volume>
          <issue>14</issue>
          <fpage>3240</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s19143240"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s19143240</pub-id>
          <pub-id pub-id-type="medline">31340548</pub-id>
          <pub-id pub-id-type="pii">s19143240</pub-id>
          <pub-id pub-id-type="pmcid">PMC6679514</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref48">
        <label>48</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Menz</surname>
              <given-names>HB</given-names>
            </name>
            <name name-style="western">
              <surname>Auhl</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Tan</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Levinger</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Roddy</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Munteanu</surname>
              <given-names>SE</given-names>
            </name>
          </person-group>
          <article-title>Biomechanical effects of prefabricated foot orthoses and rocker-sole footwear in individuals with first metatarsophalangeal joint osteoarthritis</article-title>
          <source>Arthritis Care Res (Hoboken)</source>
          <year>2016</year>
          <month>05</month>
          <volume>68</volume>
          <issue>5</issue>
          <fpage>603</fpage>
          <lpage>11</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://doi.org/10.1002/acr.22743"/>
          </comment>
          <pub-id pub-id-type="doi">10.1002/acr.22743</pub-id>
          <pub-id pub-id-type="medline">26640157</pub-id>
          <pub-id pub-id-type="pmcid">PMC5132095</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref49">
        <label>49</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kluge</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Hannink</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Pasluosta</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Klucken</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Gaßner</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Gelse</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Eskofier</surname>
              <given-names>BM</given-names>
            </name>
            <name name-style="western">
              <surname>Krinner</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Pre-operative sensor-based gait parameters predict functional outcome after total knee arthroplasty</article-title>
          <source>Gait Posture</source>
          <year>2018</year>
          <month>10</month>
          <volume>66</volume>
          <fpage>194</fpage>
          <lpage>200</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2018.08.026</pub-id>
          <pub-id pub-id-type="medline">30199778</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(18)30356-4</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref50">
        <label>50</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bloomfield</surname>
              <given-names>RA</given-names>
            </name>
            <name name-style="western">
              <surname>Williams</surname>
              <given-names>HA</given-names>
            </name>
            <name name-style="western">
              <surname>Broberg</surname>
              <given-names>JS</given-names>
            </name>
            <name name-style="western">
              <surname>Lanting</surname>
              <given-names>BA</given-names>
            </name>
            <name name-style="western">
              <surname>McIsaac</surname>
              <given-names>KA</given-names>
            </name>
            <name name-style="western">
              <surname>Teeter</surname>
              <given-names>MG</given-names>
            </name>
          </person-group>
          <article-title>Machine learning groups patients by early functional improvement likelihood based on wearable sensor instrumented preoperative timed-up-and-go tests</article-title>
          <source>J Arthroplasty</source>
          <year>2019</year>
          <month>10</month>
          <volume>34</volume>
          <issue>10</issue>
          <fpage>2267</fpage>
          <lpage>71</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://linkinghub.elsevier.com/retrieve/pii/S0883-5403(19)30546-7"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.arth.2019.05.061</pub-id>
          <pub-id pub-id-type="medline">31255408</pub-id>
          <pub-id pub-id-type="pii">S0883-5403(19)30546-7</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref51">
        <label>51</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bloomfield</surname>
              <given-names>RA</given-names>
            </name>
            <name name-style="western">
              <surname>Broberg</surname>
              <given-names>JS</given-names>
            </name>
            <name name-style="western">
              <surname>Williams</surname>
              <given-names>HA</given-names>
            </name>
            <name name-style="western">
              <surname>Lanting</surname>
              <given-names>BA</given-names>
            </name>
            <name name-style="western">
              <surname>McIsaac</surname>
              <given-names>KA</given-names>
            </name>
            <name name-style="western">
              <surname>Teeter</surname>
              <given-names>MG</given-names>
            </name>
          </person-group>
          <article-title>Machine learning and wearable sensors at preoperative assessments: functional recovery prediction to set realistic expectations for knee replacements</article-title>
          <source>Med Eng Phys</source>
          <year>2021</year>
          <month>03</month>
          <volume>89</volume>
          <fpage>14</fpage>
          <lpage>21</lpage>
          <pub-id pub-id-type="doi">10.1016/j.medengphy.2020.12.007</pub-id>
          <pub-id pub-id-type="medline">33608121</pub-id>
          <pub-id pub-id-type="pii">S1350-4533(20)30187-9</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref52">
        <label>52</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kobsar</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Osis</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Boyd</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Hettinga</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Ferber</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Wearable sensors to predict improvement following an exercise intervention in patients with knee osteoarthritis</article-title>
          <source>J Neuroeng Rehabil</source>
          <year>2017</year>
          <month>09</month>
          <day>12</day>
          <volume>14</volume>
          <issue>1</issue>
          <fpage>94</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-017-0309-z"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12984-017-0309-z</pub-id>
          <pub-id pub-id-type="medline">28899433</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12984-017-0309-z</pub-id>
          <pub-id pub-id-type="pmcid">PMC5596963</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref53">
        <label>53</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kobsar</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Ferber</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Wearable sensor data to track subject-specific movement patterns related to clinical outcomes using a machine learning approach</article-title>
          <source>Sensors (Basel)</source>
          <year>2018</year>
          <month>08</month>
          <day>27</day>
          <volume>18</volume>
          <issue>9</issue>
          <fpage>2828</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s18092828"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s18092828</pub-id>
          <pub-id pub-id-type="medline">30150560</pub-id>
          <pub-id pub-id-type="pii">s18092828</pub-id>
          <pub-id pub-id-type="pmcid">PMC6163443</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref54">
        <label>54</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sharifi Renani</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Myers</surname>
              <given-names>CA</given-names>
            </name>
            <name name-style="western">
              <surname>Zandie</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Mahoor</surname>
              <given-names>MH</given-names>
            </name>
            <name name-style="western">
              <surname>Davidson</surname>
              <given-names>BS</given-names>
            </name>
            <name name-style="western">
              <surname>Clary</surname>
              <given-names>CW</given-names>
            </name>
          </person-group>
          <article-title>Deep learning in gait parameter prediction for OA and TKA patients wearing IMU sensors</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <month>09</month>
          <day>28</day>
          <volume>20</volume>
          <issue>19</issue>
          <fpage>5553</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20195553"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20195553</pub-id>
          <pub-id pub-id-type="medline">32998329</pub-id>
          <pub-id pub-id-type="pii">s20195553</pub-id>
          <pub-id pub-id-type="pmcid">PMC7582246</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref55">
        <label>55</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Teufl</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Taetz</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Miezal</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Lorenz</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Pietschmann</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Jöllenbeck</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Fröhlich</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Bleser</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
          <article-title>Towards an inertial sensor-based wearable feedback system for patients after total hip arthroplasty: validity and applicability for gait classification with gait kinematics-based features</article-title>
          <source>Sensors (Basel)</source>
          <year>2019</year>
          <month>11</month>
          <day>16</day>
          <volume>19</volume>
          <issue>22</issue>
          <fpage>5006</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s19225006"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s19225006</pub-id>
          <pub-id pub-id-type="medline">31744141</pub-id>
          <pub-id pub-id-type="pii">s19225006</pub-id>
          <pub-id pub-id-type="pmcid">PMC6891461</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref56">
        <label>56</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Boekesteijn</surname>
              <given-names>RJ</given-names>
            </name>
            <name name-style="western">
              <surname>Smolders</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Busch</surname>
              <given-names>VJ</given-names>
            </name>
            <name name-style="western">
              <surname>Geurts</surname>
              <given-names>AC</given-names>
            </name>
            <name name-style="western">
              <surname>Smulders</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
          <article-title>Independent and sensitive gait parameters for objective evaluation in knee and hip osteoarthritis using wearable sensors</article-title>
          <source>BMC Musculoskelet Disord</source>
          <year>2021</year>
          <month>03</month>
          <day>03</day>
          <volume>22</volume>
          <issue>1</issue>
          <fpage>242</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcmusculoskeletdisord.biomedcentral.com/articles/10.1186/s12891-021-04074-2"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12891-021-04074-2</pub-id>
          <pub-id pub-id-type="medline">33658006</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12891-021-04074-2</pub-id>
          <pub-id pub-id-type="pmcid">PMC7931541</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref57">
        <label>57</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bolink</surname>
              <given-names>SA</given-names>
            </name>
            <name name-style="western">
              <surname>Brunton</surname>
              <given-names>LR</given-names>
            </name>
            <name name-style="western">
              <surname>van Laarhoven</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Lipperts</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Heyligers</surname>
              <given-names>IC</given-names>
            </name>
            <name name-style="western">
              <surname>Blom</surname>
              <given-names>AW</given-names>
            </name>
            <name name-style="western">
              <surname>Grimm</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Frontal plane pelvic motion during gait captures hip osteoarthritis related disability</article-title>
          <source>Hip Int</source>
          <year>2015</year>
          <volume>25</volume>
          <issue>5</issue>
          <fpage>413</fpage>
          <lpage>9</lpage>
          <pub-id pub-id-type="doi">10.5301/hipint.5000282</pub-id>
          <pub-id pub-id-type="medline">26351120</pub-id>
          <pub-id pub-id-type="pii">0BAF4ECF-D621-40A7-ACBA-F1DDBCB9C2DB</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref58">
        <label>58</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Xia</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Xu</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Wang</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Hunt</surname>
              <given-names>MA</given-names>
            </name>
            <name name-style="western">
              <surname>Shull</surname>
              <given-names>PB</given-names>
            </name>
          </person-group>
          <article-title>Validation of a smart shoe for estimating foot progression angle during walking gait</article-title>
          <source>J Biomech</source>
          <year>2017</year>
          <month>08</month>
          <day>16</day>
          <volume>61</volume>
          <fpage>193</fpage>
          <lpage>8</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2017.07.012</pub-id>
          <pub-id pub-id-type="medline">28780187</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(17)30371-8</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref59">
        <label>59</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Youn</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Youn</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Zeni</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>Knarr</surname>
              <given-names>BA</given-names>
            </name>
          </person-group>
          <article-title>Biomechanical gait variable estimation using wearable sensors after unilateral total knee arthroplasty</article-title>
          <source>Sensors (Basel)</source>
          <year>2018</year>
          <month>05</month>
          <day>15</day>
          <volume>18</volume>
          <issue>5</issue>
          <fpage>1577</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s18051577"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s18051577</pub-id>
          <pub-id pub-id-type="medline">29762541</pub-id>
          <pub-id pub-id-type="pii">s18051577</pub-id>
          <pub-id pub-id-type="pmcid">PMC5982146</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref60">
        <label>60</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Zügner</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Tranberg</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Timperley</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Hodgins</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Mohaddes</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Kärrholm</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Validation of inertial measurement units with optical tracking system in patients operated with total hip arthroplasty</article-title>
          <source>BMC Musculoskelet Disord</source>
          <year>2019</year>
          <month>02</month>
          <day>06</day>
          <volume>20</volume>
          <issue>1</issue>
          <fpage>52</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcmusculoskeletdisord.biomedcentral.com/articles/10.1186/s12891-019-2416-4"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12891-019-2416-4</pub-id>
          <pub-id pub-id-type="medline">30727979</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12891-019-2416-4</pub-id>
          <pub-id pub-id-type="pmcid">PMC6364439</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref61">
        <label>61</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ismailidis</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Kaufmann</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Clauss</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Pagenstert</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Eckardt</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ilchmann</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Mündermann</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Nüesch</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Kinematic changes in severe hip osteoarthritis measured at matched gait speeds</article-title>
          <source>J Orthop Res</source>
          <year>2021</year>
          <month>06</month>
          <volume>39</volume>
          <issue>6</issue>
          <fpage>1253</fpage>
          <lpage>61</lpage>
          <pub-id pub-id-type="doi">10.1002/jor.24858</pub-id>
          <pub-id pub-id-type="medline">32930435</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref62">
        <label>62</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Chang</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Hayes</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Dunlop</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Hurwitz</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Song</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Cahue</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Genge</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Sharma</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Thrust during ambulation and the progression of knee osteoarthritis</article-title>
          <source>Arthritis Rheum</source>
          <year>2004</year>
          <month>12</month>
          <volume>50</volume>
          <issue>12</issue>
          <fpage>3897</fpage>
          <lpage>903</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://doi.org/10.1002/art.20657"/>
          </comment>
          <pub-id pub-id-type="doi">10.1002/art.20657</pub-id>
          <pub-id pub-id-type="medline">15593195</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref63">
        <label>63</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Chang</surname>
              <given-names>AH</given-names>
            </name>
            <name name-style="western">
              <surname>Moisio</surname>
              <given-names>KC</given-names>
            </name>
            <name name-style="western">
              <surname>Chmiel</surname>
              <given-names>JS</given-names>
            </name>
            <name name-style="western">
              <surname>Eckstein</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Guermazi</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Prasad</surname>
              <given-names>PV</given-names>
            </name>
            <name name-style="western">
              <surname>Zhang</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Almagor</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Belisle</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Hayes</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Sharma</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>External knee adduction and flexion moments during gait and medial tibiofemoral disease progression in knee osteoarthritis</article-title>
          <source>Osteoarthritis Cartilage</source>
          <year>2015</year>
          <month>07</month>
          <volume>23</volume>
          <issue>7</issue>
          <fpage>1099</fpage>
          <lpage>106</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://linkinghub.elsevier.com/retrieve/pii/S1063-4584(15)00046-1"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.joca.2015.02.005</pub-id>
          <pub-id pub-id-type="medline">25677110</pub-id>
          <pub-id pub-id-type="pii">S1063-4584(15)00046-1</pub-id>
          <pub-id pub-id-type="pmcid">PMC4470726</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref64">
        <label>64</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Chang</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Hurwitz</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Dunlop</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Song</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Cahue</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Hayes</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Sharma</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>The relationship between toe-out angle during gait and progression of medial tibiofemoral osteoarthritis</article-title>
          <source>Ann Rheum Dis</source>
          <year>2007</year>
          <month>10</month>
          <volume>66</volume>
          <issue>10</issue>
          <fpage>1271</fpage>
          <lpage>5</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/17267516"/>
          </comment>
          <pub-id pub-id-type="doi">10.1136/ard.2006.062927</pub-id>
          <pub-id pub-id-type="medline">17267516</pub-id>
          <pub-id pub-id-type="pii">ard.2006.062927</pub-id>
          <pub-id pub-id-type="pmcid">PMC1994298</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref65">
        <label>65</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Barrios</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>Crossley</surname>
              <given-names>KM</given-names>
            </name>
            <name name-style="western">
              <surname>Davis</surname>
              <given-names>IS</given-names>
            </name>
          </person-group>
          <article-title>Gait retraining to reduce the knee adduction moment through real-time visual feedback of dynamic knee alignment</article-title>
          <source>J Biomech</source>
          <year>2010</year>
          <month>08</month>
          <day>10</day>
          <volume>43</volume>
          <issue>11</issue>
          <fpage>2208</fpage>
          <lpage>13</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/20452595"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2010.03.040</pub-id>
          <pub-id pub-id-type="medline">20452595</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(10)00202-2</pub-id>
          <pub-id pub-id-type="pmcid">PMC2914211</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref66">
        <label>66</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Fregly</surname>
              <given-names>BJ</given-names>
            </name>
            <name name-style="western">
              <surname>Reinbolt</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>Rooney</surname>
              <given-names>KL</given-names>
            </name>
            <name name-style="western">
              <surname>Mitchell</surname>
              <given-names>KH</given-names>
            </name>
            <name name-style="western">
              <surname>Chmielewski</surname>
              <given-names>TL</given-names>
            </name>
          </person-group>
          <article-title>Design of patient-specific gait modifications for knee osteoarthritis rehabilitation</article-title>
          <source>IEEE Trans Biomed Eng</source>
          <year>2007</year>
          <month>09</month>
          <volume>54</volume>
          <issue>9</issue>
          <fpage>1687</fpage>
          <lpage>95</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/17867361"/>
          </comment>
          <pub-id pub-id-type="doi">10.1109/tbme.2007.891934</pub-id>
          <pub-id pub-id-type="medline">17867361</pub-id>
          <pub-id pub-id-type="pmcid">PMC2040055</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref67">
        <label>67</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sharma</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Hurwitz</surname>
              <given-names>DE</given-names>
            </name>
            <name name-style="western">
              <surname>Thonar</surname>
              <given-names>EJ</given-names>
            </name>
            <name name-style="western">
              <surname>Sum</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>Lenz</surname>
              <given-names>ME</given-names>
            </name>
            <name name-style="western">
              <surname>Dunlop</surname>
              <given-names>DD</given-names>
            </name>
            <name name-style="western">
              <surname>Schnitzer</surname>
              <given-names>TJ</given-names>
            </name>
            <name name-style="western">
              <surname>Kirwan-Mellis</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Andriacchi</surname>
              <given-names>TP</given-names>
            </name>
          </person-group>
          <article-title>Knee adduction moment, serum hyaluronan level, and disease severity in medial tibiofemoral osteoarthritis</article-title>
          <source>Arthritis Rheum</source>
          <year>1998</year>
          <month>07</month>
          <volume>41</volume>
          <issue>7</issue>
          <fpage>1233</fpage>
          <lpage>40</lpage>
          <pub-id pub-id-type="doi">10.1002/1529-0131(199807)41:7&#60;1233::AID-ART14&#62;3.0.CO;2-L</pub-id>
          <pub-id pub-id-type="medline">9663481</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref68">
        <label>68</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Miyazaki</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Wada</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Kawahara</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Sato</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Baba</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Shimada</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritis</article-title>
          <source>Ann Rheum Dis</source>
          <year>2002</year>
          <month>07</month>
          <volume>61</volume>
          <issue>7</issue>
          <fpage>617</fpage>
          <lpage>22</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://ard.bmj.com/lookup/pmidlookup?view=long&#38;pmid=12079903"/>
          </comment>
          <pub-id pub-id-type="doi">10.1136/ard.61.7.617</pub-id>
          <pub-id pub-id-type="medline">12079903</pub-id>
          <pub-id pub-id-type="pmcid">PMC1754164</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref69">
        <label>69</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Rapp</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Brauner</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Weber</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Grau</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Mündermann</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Horstmann</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Improvement of walking speed and gait symmetry in older patients after hip arthroplasty: a prospective cohort study</article-title>
          <source>BMC Musculoskelet Disord</source>
          <year>2015</year>
          <month>10</month>
          <day>12</day>
          <volume>16</volume>
          <issue>1</issue>
          <fpage>291</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcmusculoskeletdisord.biomedcentral.com/articles/10.1186/s12891-015-0755-3"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12891-015-0755-3</pub-id>
          <pub-id pub-id-type="medline">26459628</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12891-015-0755-3</pub-id>
          <pub-id pub-id-type="pmcid">PMC4603916</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref70">
        <label>70</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Singh</surname>
              <given-names>OP</given-names>
            </name>
            <name name-style="western">
              <surname>Gambhir</surname>
              <given-names>IS</given-names>
            </name>
            <name name-style="western">
              <surname>Saraf</surname>
              <given-names>SK</given-names>
            </name>
            <name name-style="western">
              <surname>Deshpande</surname>
              <given-names>SB</given-names>
            </name>
            <name name-style="western">
              <surname>Singh</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
          <article-title>Quantitative assessment of muscle activity and joint load in braced and unbraced osteoarthritis knee by external strain gauge sensor</article-title>
          <source>Indian J Physiol Pharmacol</source>
          <year>2016</year>
          <month>04</month>
          <volume>60</volume>
          <issue>2</issue>
          <fpage>145</fpage>
          <lpage>54</lpage>
          <pub-id pub-id-type="medline">29809372</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref71">
        <label>71</label>
        <nlm-citation citation-type="web">
          <article-title>Using telehealth to expand access to essential health services during the COVID-19 pandemic</article-title>
          <source>Centers for Disease Control and Prevention</source>
          <access-date>2022-05-01</access-date>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.cdc.gov/coronavirus/2019-ncov/hcp/telehealth.html">https://www.cdc.gov/coronavirus/2019-ncov/hcp/telehealth.html</ext-link>
          </comment>
        </nlm-citation>
      </ref>
      <ref id="ref72">
        <label>72</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kobsar</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Masood</surname>
              <given-names>Z</given-names>
            </name>
            <name name-style="western">
              <surname>Khan</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Khalil</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Kiwan</surname>
              <given-names>MY</given-names>
            </name>
            <name name-style="western">
              <surname>Ridd</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Tobis</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Wearable inertial sensors for gait analysis in adults with osteoarthritis-a scoping review</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <month>12</month>
          <day>13</day>
          <volume>20</volume>
          <issue>24</issue>
          <fpage>7143</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20247143"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20247143</pub-id>
          <pub-id pub-id-type="medline">33322187</pub-id>
          <pub-id pub-id-type="pii">s20247143</pub-id>
          <pub-id pub-id-type="pmcid">PMC7763184</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref73">
        <label>73</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Follis</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>Z</given-names>
            </name>
            <name name-style="western">
              <surname>Mishra</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Howe</surname>
              <given-names>CL</given-names>
            </name>
            <name name-style="western">
              <surname>Toosizadeh</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Dohm</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Comparison of wearable sensor to traditional methods in functional outcome measures: a systematic review</article-title>
          <source>J Orthop Res</source>
          <year>2021</year>
          <month>10</month>
          <volume>39</volume>
          <issue>10</issue>
          <fpage>2093</fpage>
          <lpage>102</lpage>
          <pub-id pub-id-type="doi">10.1002/jor.24950</pub-id>
          <pub-id pub-id-type="medline">33300119</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref74">
        <label>74</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Cucinotta</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Vanelli</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>WHO declares COVID-19 a pandemic</article-title>
          <source>Acta Biomed</source>
          <year>2020</year>
          <month>03</month>
          <day>19</day>
          <volume>91</volume>
          <issue>1</issue>
          <fpage>157</fpage>
          <lpage>60</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/32191675"/>
          </comment>
          <pub-id pub-id-type="doi">10.23750/abm.v91i1.9397</pub-id>
          <pub-id pub-id-type="medline">32191675</pub-id>
          <pub-id pub-id-type="pmcid">PMC7569573</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref75">
        <label>75</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Olayiwola</surname>
              <given-names>JN</given-names>
            </name>
            <name name-style="western">
              <surname>Magaña</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Harmon</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Nair</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Esposito</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Harsh</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Forrest</surname>
              <given-names>LA</given-names>
            </name>
            <name name-style="western">
              <surname>Wexler</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Telehealth as a bright spot of the COVID-19 pandemic: recommendations from the virtual frontlines ("Frontweb")</article-title>
          <source>JMIR Public Health Surveill</source>
          <year>2020</year>
          <month>06</month>
          <day>25</day>
          <volume>6</volume>
          <issue>2</issue>
          <fpage>e19045</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://publichealth.jmir.org/2020/2/e19045/"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/19045</pub-id>
          <pub-id pub-id-type="medline">32479413</pub-id>
          <pub-id pub-id-type="pii">v6i2e19045</pub-id>
          <pub-id pub-id-type="pmcid">PMC7318864</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref76">
        <label>76</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Gaba</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Bhatt</surname>
              <given-names>DL</given-names>
            </name>
          </person-group>
          <article-title>The COVID-19 pandemic: a catalyst to improve clinical trials</article-title>
          <source>Nat Rev Cardiol</source>
          <year>2020</year>
          <month>11</month>
          <day>01</day>
          <volume>17</volume>
          <issue>11</issue>
          <fpage>673</fpage>
          <lpage>5</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/32873977"/>
          </comment>
          <pub-id pub-id-type="doi">10.1038/s41569-020-00439-7</pub-id>
          <pub-id pub-id-type="medline">32873977</pub-id>
          <pub-id pub-id-type="pii">10.1038/s41569-020-00439-7</pub-id>
          <pub-id pub-id-type="pmcid">PMC7461742</pub-id>
        </nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>
